Ray contribution masks for structure adaptive sinogram filtering M Balda, J Hornegger, B Heismann IEEE transactions on medical imaging 31 (6), 1228-1239, 2012 | 136 | 2012 |
A comparative error analysis of current time-of-flight sensors P Fürsattel, S Placht, M Balda, C Schaller, H Hofmann, A Maier, C Riess IEEE Transactions on Computational Imaging 2 (1), 27-41, 2015 | 111 | 2015 |
Real-time range imaging in health care: A survey S Bauer, A Seitel, H Hofmann, T Blum, J Wasza, M Balda, HP Meinzer, ... Time-of-Flight and Depth Imaging. Sensors, Algorithms, and Applications …, 2013 | 83 | 2013 |
Rochade: Robust checkerboard advanced detection for camera calibration S Placht, P Fürsattel, EA Mengue, H Hofmann, C Schaller, M Balda, ... Computer Vision–ECCV 2014: 13th European Conference, Zurich, Switzerland …, 2014 | 81 | 2014 |
Fast time‐of‐flight camera based surface registration for radiotherapy patient positioning S Placht, J Stancanello, C Schaller, M Balda, E Angelopoulou Medical physics 39 (1), 4-17, 2012 | 71 | 2012 |
Quantitative image‐based spectral reconstruction for computed tomography B Heismann, M Balda Medical physics 36 (10), 4471-4485, 2009 | 48 | 2009 |
Lookup table-based simulation of directly-converting counting X-ray detectors for computed tomography M Balda, D Niederlöhner, B Kreisler, J Durst, B Heismann 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC), 2588-2593, 2009 | 23 | 2009 |
OCPAD—Occluded checkerboard pattern detector P Fuersattel, S Dotenco, S Placht, M Balda, A Maier, C Riess 2016 IEEE Winter Conference on Applications of Computer Vision (WACV), 1-9, 2016 | 22 | 2016 |
Ground truth for evaluating time of flight imaging R Nair, S Meister, M Lambers, M Balda, H Hofmann, A Kolb, ... Time-of-Flight and Depth Imaging. Sensors, Algorithms, and Applications …, 2013 | 15 | 2013 |
Computed tomography O Taubmann, M Berger, M Bögel, Y Xia, M Balda, A Maier Medical Imaging Systems: An Introductory Guide, 147-189, 2018 | 14 | 2018 |
Improvement and Evaluation of a Time-of-Flight-based Patient Positioning System. S Placht, C Schaller, M Balda, A Adelt, C Ulrich, J Hornegger Bildverarbeitung für die Medizin, 177-181, 2010 | 8 | 2010 |
Correction of intensity inhomogeneities utilizing histogram-based regularization F Jäger, M Balda, J Hornegger 4th Russian Conference on Biomedical Engineering, 23-27, 2008 | 7 | 2008 |
Value-based noise reduction for low-dose dual-energy computed tomography M Balda, B Heismann, J Hornegger Medical Image Computing and Computer-Assisted Intervention–MICCAI 2010: 13th …, 2010 | 6 | 2010 |
Non-Stationary CT Image Noise Spectrum Analysis. M Balda, B Heismann, J Hornegger Bildverarbeitung für die Medizin, 191-195, 2010 | 6 | 2010 |
Quantitative Computed Tomography M Balda PQDT-Global, 2011 | 5 | 2011 |
Evaluation of an image-based algorithm for quantitative spectral CT applications BJ Heismann, M Balda Medical Imaging 2010: Physics of Medical Imaging 7622, 1157-1164, 2010 | 3 | 2010 |
Look-up table-based simulation of scintillation detectors in computed tomography M Balda, S Wirth, D Niederlohner, B Heismann, J Hornegger 2008 IEEE Nuclear Science Symposium Conference Record, 4028-4033, 2008 | 2 | 2008 |
Arrangement and method for increasing the measurement accuracy in the three-dimensional measurement of objects S Placht, C Schaller, M Balda, B Kayser US Patent App. 17/971,767, 2023 | | 2023 |
Benutzungsschnittstellen zur Vermittlung erkannter Emotionen Y Bachteler, M Balda, MC Kindsmüller Mensch und Computer 2018-Tagungsband, 2018 | | 2018 |
Sensakovic, Samantha J. Passen, Roger Engelmann, and Heber MacMahon; 36 (12), 5675-82. Arrans, Rafael—see Miras, Hector 36 (9), 3866-9. Arvanitis, CD—Signal and noise … M Åslund, V Ataeinia, E Atalar, A Attili, M Aubin, S Aubin, V Auboiroux, ... Medical Physics 36 (12), 5774, 2009 | | 2009 |