Takip et
Suat ilhan
Suat ilhan
Istanbul Technical University, Electrical Engineering Department
itu.edu.tr üzerinde doğrulanmış e-posta adresine sahip
Başlık
Alıntı yapanlar
Alıntı yapanlar
Yıl
380 kV corona ring optimization for AC voltages
S Ilhan, A Ozdemir
IEEE Transactions on Dielectrics and Electrical Insulation 18 (2), 408-417, 2011
492011
Comparative properties of HTV silicone rubber for composite insulators—ATH and silica fillers
S Ilhan, D Tuzun, A Ozdemir
IEEE Transactions on Dielectrics and Electrical Insulation 28 (2), 414-422, 2021
302021
AC and transient electric field distributions along a 380 kV V-string insulator
S Ilhan, A Ozdemir, SH Jayaram, EA Cherney
2012 IEEE International Symposium on Electrical Insulation, 399-403, 2012
262012
Comparative tests on RTV silicone rubber coated porcelain suspension insulators in a salt-fog chamber
S Ilhan, EA Cherney
IEEE Transactions on Dielectrics and Electrical Insulation 25 (3), 947-953, 2018
252018
Numerical and experimental investigation of the effects of pollution on glass suspension-type insulators
S İlhan, A Ozdemir, SH Jayaram, EA Cherney
IEEE Transactions on Dielectrics and Electrical Insulation 22 (5), 2987-2994, 2015
252015
Workmanship defect classification in medium voltage cable terminations with convolutional neural network
HI Uckol, S Ilhan, A Ozdemir
Electric Power Systems Research 194, 107105, 2021
242021
Impacts of corona rings on the insulation performance of composite polymer insulator strings
S İlhan, A Ozdemir, H Ismailoglu
IEEE Transactions on Dielectrics and Electrical Insulation 22 (3), 1605-1612, 2015
232015
Simulations of pollution and their effects on the electrical performance of glass suspension insulators
S Ilhan, A Ozdemir, SH Jayaram, EA Cherney
2012 Annual Report Conference on Electrical Insulation and Dielectric …, 2012
232012
Effects of corona ring design upon impulse voltage withstand level of 380 kV V-strings
S Ilhan, A Ozdemir
IEEE Transactions on Dielectrics and Electrical Insulation 18 (5), 1638-1646, 2011
232011
Design and technical analysis of 500–600 kV HVDC transmission system for Turkey
A Font, S Ilhan, H Ismailoglu, FE Cortes, A Özdemir
2017 10th International Conference on Electrical and Electronics Engineering …, 2017
172017
High impedance fault localization: A comprehensive review
E Baharozu, S Ilhan, G Soykan
Electric Power Systems Research 214, 108892, 2023
152023
DC corona characteristics derived from corona cage tests and simulations
A Font, YT Solak, S Ilhan, A Ozdemir, H Ismailoglu, FE Cortes
IEEE Transactions on Dielectrics and Electrical Insulation 26 (6), 1867-1875, 2019
152019
DC and AC electric field analysis and experimental verification of a silicone rubber insulator
HI Uckol, B Karaca, S Ilhan
Electrical Engineering 102, 503-514, 2020
142020
Viability of fillers in HTV silicone rubber in the AC and DC inclined plane tests
RA Ghunem, S Ilhan, HI Uckol, D Tuzun, Y Hadjadj
IEEE Transactions on Dielectrics and Electrical Insulation 28 (6), 2144-2151, 2021
122021
Partial Discharge pattern classification based on deep learning for defect identification in MV cable terminations
HI Uckol, S Ilhan, A Ozdemir
2020 IEEE International Conference on High Voltage Engineering and …, 2020
112020
Identification of corona discharges based on wavelet scalogram images with deep convolutional neural networks
HI Uckol, S Ilhan
Electric Power Systems Research 224, 109712, 2023
102023
Voltage distribution effects of non-uniform units in suspension strings
S Ilhan, A Ozdemir
2007 IEEE Lausanne Power Tech, 801-806, 2007
102007
Effects of corona ring design on electric field intensity and potential distribution along an insulator string
S İlhan, A Özdemir
International Conference of Electrical and Electronics, 142-146, 2007
92007
Characterization of DC corona discharge current pulses using high-frequency measurement techniques
HI Uckol, S Ilhan
Measurement 218, 113154, 2023
82023
Flashover performance of 380 kV V-strings with composite insulators under lightning and switching impulses
S Ilhan, A Ozdemir
2009 IEEE Bucharest PowerTech, 1-6, 2009
82009
Sistem, işlemi şu anda gerçekleştiremiyor. Daha sonra yeniden deneyin.