Square-wave voltammetric determination of propranolol and atenolol in pharmaceuticals using a boron-doped diamond electrode ER Sartori, RA Medeiros, RC Rocha-Filho, O Fatibello-Filho Talanta 81 (4-5), 1418-1424, 2010 | 164 | 2010 |
Square-wave voltammetric determination of acetylsalicylic acid in pharmaceutical formulations using a boron-doped diamond electrode without the need of previous alkaline … ER Sartori, RA Medeiros, RC Rocha-Filho, O Fatibello-Filho Journal of the Brazilian Chemical Society 20, 360-366, 2009 | 107 | 2009 |
Evaluation of boron-doped diamond electrode for simultaneous voltammetric determination of hydrochlorothiazide and losartan in pharmaceutical formulations MCG Santos, CRT Tarley, LH Dall’Antonia, ER Sartori Sensors and Actuators B: Chemical 188, 263-270, 2013 | 100 | 2013 |
Simultaneous square‐wave voltammetric determination of paracetamol, caffeine and orphenadrine in pharmaceutical formulations using a cathodically pretreated boron‐doped diamond … APP Eisele, DN Clausen, CRT Tarley, LH Dall'Antonia, ER Sartori Electroanalysis 25 (7), 1734-1741, 2013 | 83 | 2013 |
An improved method for simultaneous square-wave voltammetric determination of amlodipine and enalapril at multi-walled carbon nanotubes paste electrode based on effect of … CF Valezi, EH Duarte, GR Mansano, LH Dall’Antonia, CRT Tarley, ... Sensors and Actuators B: Chemical 205, 234-243, 2014 | 77 | 2014 |
Differential pulse voltammetric determination of sildenafil citrate (Viagra®) in pharmaceutical formulations using a boron-doped diamond electrode EF Batista, ER Sartori, RA Medeiros, RC Rocha-Filho, O Fatibello-Filho Analytical Letters 43 (6), 1046-1054, 2010 | 74 | 2010 |
Voltammetric determination of verapamil and propranolol using a glassy carbon electrode modified with functionalized multiwalled carbon nanotubes within a poly (allylamine … GG Oliveira, DC Azzi, FC Vicentini, ER Sartori, O Fatibello-Filho Journal of Electroanalytical Chemistry 708, 73-79, 2013 | 64 | 2013 |
Sensitive square-wave voltammetric determination of tadalafil (Cialis®) in pharmaceutical samples using a cathodically pretreated boron-doped diamond electrode ER Sartori, DN Clausen, IMR Pires, CAR Salamanca-Neto Diamond and Related Materials 77, 153-158, 2017 | 60 | 2017 |
Indirect determination of sulfite using a polyphenol oxidase biosensor based on a glassy carbon electrode modified with multi-walled carbon nanotubes and gold nanoparticles … ER Sartori, FC Vicentini, O Fatibello-Filho Talanta 87, 235-242, 2011 | 60 | 2011 |
Synthesis of CdO nanoparticles using direct chemical precipitation method: Fabrication of novel voltammetric sensor for square wave voltammetry determination of chlorpromazine … S Ahmadzadeh, F Karimi, N Atar, ER Sartori, E Faghih-Mirzaei, ... Inorganic and Nano-Metal Chemistry 47 (3), 347-353, 2017 | 57 | 2017 |
Electroanalytical application of a boron-doped diamond electrode: Improving the simultaneous voltammetric determination of amlodipine and valsartan in urine and combined dosage … GR Mansano, APP Eisele, LH Dall’Antonia, S Afonso, ER Sartori Journal of Electroanalytical Chemistry 738, 188-194, 2015 | 57 | 2015 |
Differential pulse voltammetric method for the individual and simultaneous determination of antihypertensive drug metoprolol and its association with hydrochlorothiazide in … CAR Salamanca-Neto, APP Eisele, VG Resta, J Scremin, ER Sartori Sensors and Actuators B: Chemical 230, 630-638, 2016 | 55 | 2016 |
Exploring the exocellular fungal biopolymer botryosphaeran for laccase-biosensor architecture and application to determine dopamine and spironolactone JH Coelho, APP Eisele, CF Valezi, GJ Mattos, JG Schirmann, RFH Dekker, ... Talanta 204, 475-483, 2019 | 54 | 2019 |
Electrochemical study for the simultaneous determination of phenolic compounds and emerging pollutant using an electroanalytical sensing system based on carbon nanotubes … FA Gorla, EH Duarte, ER Sartori, CRT Tarley Microchemical Journal 124, 65-75, 2016 | 54 | 2016 |
Square-wave voltammetric determination of bezafibrate in pharmaceutical formulations using a cathodically pretreated boron-doped diamond electrode JA Ardila, ER Sartori, RC Rocha-Filho, O Fatibello-Filho Talanta 103, 201-206, 2013 | 54 | 2013 |
Highly improved simultaneous herbicides determination in water samples by differential pulse voltammetry using boron-doped diamond electrode and solid phase extraction on cross … EH Duarte, J Casarin, ER Sartori, CRT Tarley Sensors and Actuators B: Chemical 255, 166-175, 2018 | 51 | 2018 |
Advanced sensing performance towards simultaneous determination of quaternary mixture of antihypertensives using boron-doped diamond electrode JT Moraes, CAR Salamanca-Neto, Ľ Švorc, ER Sartori Microchemical Journal 134, 173-180, 2017 | 47 | 2017 |
Electrochemical evaluation of a boron-doped diamond electrode for simultaneous determination of an antihypertensive ternary mixture of amlodipine, hydrochlorothiazide and … GR Mansano, APP Eisele, ER Sartori Analytical Methods 7 (3), 1053-1060, 2015 | 47 | 2015 |
Assessment of the use of boron-doped diamond electrode for highly sensitive voltammetric determination of the azo-dye carmoisine E− 122 in food and environmental matrices L Micheletti, B Coldibeli, CAR Salamanca-Neto, LC Almeida, ER Sartori Talanta 220, 121417, 2020 | 44 | 2020 |
Simultaneous determination of hydrochlorothiazide and valsartan in combined dosage forms: Electroanalytical performance of cathodically pretreated boron-doped diamond electrode APP Eisele, GR Mansano, FM de Oliveira, J Casarin, CRT Tarley, ... Journal of Electroanalytical Chemistry 732, 46-52, 2014 | 41 | 2014 |