A complete model of wet cooling towers with fouling in fills BA Qureshi, SM Zubair Applied thermal engineering 26 (16), 1982-1989, 2006 | 114 | 2006 |
A comprehensive design and performance evaluation study of counter flow wet cooling towers BA Qureshi, SM Zubair International Journal of Refrigeration 27 (8), 914-923, 2004 | 110 | 2004 |
A comprehensive design and rating study of evaporative coolers and condensers. Part I. Performance evaluation BA Qureshi, SM Zubair International journal of refrigeration 29 (4), 645-658, 2006 | 95 | 2006 |
Second-law-based performance evaluation of cooling towers and evaporative heat exchangers BA Qureshi, SM Zubair International journal of thermal sciences 46 (2), 188-198, 2007 | 94 | 2007 |
Experimental energetic analysis of a vapor compression refrigeration system with dedicated mechanical sub-cooling BA Qureshi, M Inam, MA Antar, SM Zubair Applied Energy 102, 1035-1041, 2013 | 89 | 2013 |
The effect of refrigerant combinations on performance of a vapor compression refrigeration system with dedicated mechanical sub-cooling BA Qureshi, SM Zubair International Journal of Refrigeration 35 (1), 47-57, 2012 | 89 | 2012 |
Mechanical sub-cooling vapor compression systems: Current status and future directions BA Qureshi, SM Zubair International Journal of Refrigeration 36 (8), 2097-2110, 2013 | 70 | 2013 |
Modeling of droplet entrainment in co-current annular two-phase flow: A new approach A Al-Sarkhi, C Sarica, B Qureshi International Journal of Multiphase Flow, 2011 | 70 | 2011 |
Application of exergy analysis to various psychrometric processes BA Qureshi, SM Zubair International journal of energy research 27 (12), 1079-1094, 2003 | 68 | 2003 |
A Comprehensive Review of Saline Water Correlations and Data: Part II—Thermophysical Properties NAA Qasem, MM Generous, BA Qureshi, SM Zubair Arabian Journal for Science and Engineering, 1-39, 2021 | 65 | 2021 |
Performance degradation of a vapor compression refrigeration system under fouled conditions BA Qureshi, SM Zubair International Journal of Refrigeration 34 (4), 1016-1027, 2011 | 63 | 2011 |
The impact of fouling on the condenser of a vapor compression refrigeration system: An experimental observation BA Qureshi, SM Zubair International Journal of Refrigeration 38, 260-266, 2014 | 58 | 2014 |
The impact of fouling on performance of a vapor compression refrigeration system with integrated mechanical sub-cooling system BA Qureshi, SM Zubair Applied Energy 92, 750-762, 2012 | 56 | 2012 |
The impact of fouling on performance evaluation of evaporative coolers and condensers BA Qureshi, SM Zubair International journal of energy research 29 (14), 1313-1330, 2005 | 55 | 2005 |
Exergetic analysis of a brackish water reverse osmosis desalination unit with various energy recovery systems BA Qureshi, SM Zubair Energy 93, 256-265, 2015 | 52 | 2015 |
Prediction of evaporation losses in wet cooling towers BA Qureshi, SM Zubair Heat transfer engineering 27 (9), 86-92, 2006 | 51 | 2006 |
A comprehensive design and rating study of evaporative coolers and condensers. Part II. Sensitivity analysis BA Qureshi, SM Zubair International journal of refrigeration 29 (4), 659-668, 2006 | 47 | 2006 |
Exergo-economic analysis of a seawater reverse osmosis desalination plant with various retrofit options MA Jamil, BA Qureshi, SM Zubair Desalination 401, 88-98, 2017 | 46 | 2017 |
Improvement in design of electrodialysis desalination plants by considering the Donnan potential NAA Qasem, BA Qureshi, SM Zubair Desalination 441, 62-76, 2018 | 45 | 2018 |
Design and performance evaluation of reverse osmosis desalination systems: An emphasis on fouling modeling BA Qureshi, SM Zubair, AK Sheikh, A Bhujle, S Dubowsky Applied Thermal Engineering 60 (1), 208-217, 2013 | 41 | 2013 |