Wear simulation of total hip prostheses with polyethylene against CoCr, alumina and diamond-like carbon V Saikko, T Ahlroos, O Calonius, J Keränen Biomaterials 22 (12), 1507-1514, 2001 | 221 | 2001 |
A multidirectional motion pin‐on‐disk wear test method for prosthetic joint materials V Saikko Journal of Biomedical Materials Research: An Official Journal of The Society …, 1998 | 170 | 1998 |
Effect of contact pressure on wear and friction of ultra-high molecular weight polyethylene in multidirectional sliding V Saikko Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2006 | 160 | 2006 |
Wear of the polyethylene acetabular cup: metallic and ceramic heads compared in a hip simulator VO Saikko, PO Paavolainen, P Slätis Acta Orthopaedica Scandinavica 64 (4), 391-402, 1993 | 139 | 1993 |
Slide track analysis of the relative motion between femoral head and acetabular cup in walking and in hip simulators V Saikko, O Calonius Journal of Biomechanics 35 (4), 455-464, 2002 | 132 | 2002 |
Effect of counterface roughness on the wear of conventional and crosslinked ultrahigh molecular weight polyethylene studied with a multi‐directional motion pin‐on‐disk device V Saikko, O Calonius, J Keränen Journal of Biomedical Materials Research: An Official Journal of The Society …, 2001 | 118 | 2001 |
Type of motion and lubricant in wear simulation of polyethylene acetabular cup V Saikko, T Ahlroos Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 1999 | 113 | 1999 |
Effect of lubricant protein concentration on the wear of ultra-high molecular weight polyethylene sliding against a CoCr counterface V Saikko J. Trib. 125 (3), 638-642, 2003 | 104 | 2003 |
Advances in tribological testing of artificial joint biomaterials using multidirectional pin-on-disk testers D Baykal, RS Siskey, H Haider, V Saikko, T Ahlroos, SM Kurtz Journal of the mechanical behavior of biomedical materials 31, 117-134, 2014 | 102 | 2014 |
Wear and friction properties of prosthetic joint materials evaluated on a reciprocating pin-on-flat apparatus V Saikko Wear 166 (2), 169-178, 1993 | 96 | 1993 |
A 12-station anatomic hip joint simulator V Saikko Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2005 | 94 | 2005 |
Wear of conventional and cross‐linked ultra‐high‐molecular‐weight polyethylene acetabular cups against polished and roughened CoCr femoral heads in a biaxial hip simulator V Saikko, O Calonius, J Keränen Journal of Biomedical Materials Research: An Official Journal of The Society …, 2002 | 92 | 2002 |
Wear simulation of UHMWPE for total hip replacement with a multidirectional motion pin‐on‐disk device: Effects of counterface material, contact area, and lubricant V Saikko, T Ahlroos Journal of Biomedical Materials Research: An Official Journal of The Society …, 2000 | 92 | 2000 |
Slide track analysis of eight contemporary hip simulator designs O Calonius, V Saikko Journal of Biomechanics 35 (11), 1439-1450, 2002 | 89 | 2002 |
A three-axis hip joint simulator for wear and friction studies on total hip prostheses VO Saikko Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 1996 | 87 | 1996 |
A hip wear simulator with 100 test stations V Saikko Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2005 | 76 | 2005 |
Phospholipids as boundary lubricants in wear tests of prosthetic joint materials V Saikko, T Ahlroos Wear 207 (1-2), 86-91, 1997 | 76 | 1997 |
Wear of the polyethylene acetabular cup: the effect of head material, head diameter, and cup thickness studied with a hip simulator VO Saikko Acta Orthopaedica Scandinavica 66 (6), 501-506, 1995 | 72 | 1995 |
A five-station hip joint simulator for wear rate studies V Saikko, P Paavolainen, M Kleimola, P Slätis Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 1992 | 72 | 1992 |
Low wear and friction in alumina/alumina total hip joints: a hip simulator study V Saikko, HG Pfaff Acta Orthopaedica Scandinavica 69 (5), 443-448, 1998 | 66 | 1998 |