Research and Technologies for next-generation high-temperature data centers–State-of-the-arts and future perspectives
Data centers have attracted increasing attention worldwide over the last decades due to
their high energy consumption. Cooling accounts for about 30–40% of the total energy …
their high energy consumption. Cooling accounts for about 30–40% of the total energy …
Data centers cooling: a critical review of techniques, challenges, and energy saving solutions
In order to increase data centers' efficiency and performance, a proper cooling system
should be applied. This article provides a comprehensive assessment which explores …
should be applied. This article provides a comprehensive assessment which explores …
A critical review on the thermal management of data center for local hotspot elimination
R Zhao, Y Du, X Yang, Z Zhou, W Wang, X Yang - Energy and Buildings, 2023 - Elsevier
The data centers consume a significant amount of energy, with cooling demand accounting
for roughly 40% of the total energy usage. The primary reason for this is the presence of the …
for roughly 40% of the total energy usage. The primary reason for this is the presence of the …
Multi-objective optimization of supply air jet enhancing airflow uniformity in data center using Taguchi/CRITIC/TOPSIS triple method
Z Yang, B Niu, Y Pan, Y Chen - Building and Environment, 2023 - Elsevier
Jet fans have been introduced into under-floor air distribution systems as an active local
measure to reduce hot spot temperatures and improve airflow distribution uniformity in data …
measure to reduce hot spot temperatures and improve airflow distribution uniformity in data …
Optimization of underfloor air distribution systems for data centers based on orthogonal test method: A case study
With the rapid development of cloud computing and artificial intelligence, it has been
increasingly significant to reduce the energy consumption of data centers (DCs) by …
increasingly significant to reduce the energy consumption of data centers (DCs) by …
An experimental and numerical investigation of novel solution for energy management enhancement in data centers using underfloor plenum porous obstructions
This investigation focuses on improving the airflow distribution in data centers. In many data
centers vortices form in the plenum during operations. These vortices cause spatial and …
centers vortices form in the plenum during operations. These vortices cause spatial and …
Experimental and numerical investigation on thermal performance of data center via fan-wall free cooling technology
With the rapid increase in the scale of data center (DC) construction, DC air conditioning
energy consumption has attracted wide attention over the past years. As the DCs are located …
energy consumption has attracted wide attention over the past years. As the DCs are located …
Energy saving analysis of evaporative cooling composite air conditioning system for data centers
Z Han, X Sun, H Wei, Q Ji, D Xue - Applied Thermal Engineering, 2021 - Elsevier
An evaporative cooling composite air conditioning system aimed at enhancing energy
efficiency of data centers was proposed. Furthermore, the mathematical models on the base …
efficiency of data centers was proposed. Furthermore, the mathematical models on the base …
[HTML][HTML] Experimental study on the performance of a tree-shaped mini-channel liquid cooling heat sink
S Wu, K Zhang, G Song, J Zhu, B Yao - Case Studies in Thermal …, 2022 - Elsevier
Characteristic of high heat dissipation of semiconductor electronic products require the
cooling systems operating throughout the year, which inevitably causes a huge energy …
cooling systems operating throughout the year, which inevitably causes a huge energy …
[HTML][HTML] Thermal management and performance enhancement of data centers architectures using aligned/staggered in-row cooling arrangements
This research investigates the effects of using aligned/staggered arrangements of cooling
units and top aisles containments on the performance of in-rows cooling architectures of …
units and top aisles containments on the performance of in-rows cooling architectures of …