[HTML][HTML] Assessment, repair, and retrofitting of masonry structures: A comprehensive review

A Keshmiry, S Hassani, U Dackermann, J Li - Construction and Building …, 2024 - Elsevier
In the history of our civilization, masonry structures date back thousands of years.
Considering the different types, geometries, and arrangements of masonry components, as …

Seismic and thermal retrofitting of masonry buildings with fiber reinforced composite systems: a state of the art review

A Majumder, F Stochino, F Fraternali… - International Journal of …, 2021 - iris.unica.it
Old masonry buildings represent the largest part of traditional constructions. Generally, they
are both seismically vulnerable and thermally dispersive. Therefore, the need for seismic …

In-plane shear capacity of tuff masonry walls with traditional and innovative Composite Reinforced Mortars (CRM)

M Del Zoppo, M Di Ludovico, A Balsamo… - Construction and Building …, 2019 - Elsevier
The effectiveness of reinforced plasters and Composite Reinforced Mortars (CRM) for
increasing the in-plane shear capacity of masonry walls was investigated on a series of 32 …

Cyclic in-plane behavior of unreinforced and confined masonry walls retrofitted by shotcrete: Experimental investigation

SRS Rezaee, M Soltani, M Nikooravesh - Engineering Structures, 2022 - Elsevier
This study aimed to investigate the efficiency of shotcrete retrofitting method for seismic
rehabilitation of conventional unreinforced and confined masonry walls. In this regard, six …

Extended fragility surfaces for unreinforced masonry walls using vision-derived damage parameters

AH Asjodi, KM Dolatshahi - Engineering Structures, 2023 - Elsevier
This paper introduces a novel methodology for identifying the post-earthquake damage
states of unreinforced masonry walls using visual damage features. Current guidelines …

Shake table test of a masonry building retrofitted with shotcrete

A Ghezelbash, K Beyer, KM Dolatshahi… - Engineering …, 2020 - Elsevier
This paper presents the results of a series of shake table tests carried out on a half-scale
single-story unreinforced masonry building with asymmetric openings. First, the unretrofitted …

Structural and thermal retrofitting of masonry walls: An integrated cost-analysis approach for the Italian context

F Mistretta, F Stochino, M Sassu - Building and Environment, 2019 - Elsevier
Constructions ageing is a relevant problem in developed country like Italy. In particular, in
case of existing masonry buildings, retrofitting interventions aimed at improving structural …

Quantifying hybrid failure modes of unreinforced masonry walls through experimental data analysis

AH Asjodi, S Saeidi, KM Dolatshahi… - Journal of Structural …, 2024 - ascelibrary.org
Failure mode identification in unreinforced masonry (URM) walls is a challenging task
because of the presence of multiple damage mechanisms, including so-called hybrid …

[HTML][HTML] Two-step homogenized elastic model for in-plane analysis of coated masonry walls

S Di Nino, A Luongo - European Journal of Mechanics-A/Solids, 2023 - Elsevier
A two-step homogenization procedure is used to identify the (membrane) macroscopic
elastic constants of coated masonry walls, solicited in their plane. The two steps deal …

[HTML][HTML] Experimental study of bond behavior on sprayed and poured mortar–brick interface with latex bonding agent under conventional and humid environments

D Huang, A Albareda, O Pons - Journal of Building Engineering, 2023 - Elsevier
Sprayed mortars are able to enhance masonry walls, particularly for improving the
resistance of the existing building stock to horizontal forces such as seismic. This is the case …