Biomechanical analysis of printable functionally graded material (FGM) dental implants for different bone densities
The long-term success of a dental implant is related to the material and design of the
implant, and bone density. Conventional implants cause stress-shielding due to a mismatch …
implant, and bone density. Conventional implants cause stress-shielding due to a mismatch …
Biomechanical performance of Ti-PEEK dental implants in bone: An in-silico analysis
Stress-shielding is caused by a significant mismatch in stiffness between bone tissue and Ti
alloy dental implants. Therefore, in this study, a Ti-PEEK composite implant was examined …
alloy dental implants. Therefore, in this study, a Ti-PEEK composite implant was examined …
A comprehensive biomechanical evaluation of length and diameter of dental implants using finite element analyses: A systematic review
P Qiu, R Cao, Z Li, Z Fan - Heliyon, 2024 - cell.com
Background With a wide range of dental implants currently used in clinical scenarios,
evidence is limited on selecting the type of dental implant best suited to endure the biting …
evidence is limited on selecting the type of dental implant best suited to endure the biting …
Finite element analysis of the effect of porosity on biomechanical behaviour of functionally graded dental implant
The disparity between the bone's and the dental implant's stiffness generates problems for
patients, such as implant failure, bone resorption and patient discomfort. The idea of …
patients, such as implant failure, bone resorption and patient discomfort. The idea of …
Functionally graded ceramics (FGC) dental abutment with implant-supported cantilever crown: finite element analysis
The design factor of the dental abutment may affect the stability of the implant. Therefore,
choosing the right abutment is required for the patient's long-term therapy. The aim of this …
choosing the right abutment is required for the patient's long-term therapy. The aim of this …
Effect of crown retention systems and loading direction on the stress magnitude of posterior implant-supported restorations: A 3D-FEA
This study aimed to investigate the effect of four retention systems for implant-supported
posterior crowns under compressive loading using three-dimensional finite element …
posterior crowns under compressive loading using three-dimensional finite element …
The effect of porous compliance bushings in a dental implant on the distribution of occlusal loads
Porous dental implants are clinically used, but the mechanism of load distribution for
stepped implant shaft surrounded by compliance bushings is still not known, especially for …
stepped implant shaft surrounded by compliance bushings is still not known, especially for …
Influence of surface texturing and coatings on mechanical properties and integration with bone tissue: An in silico study
Introduction This investigation delves into the mechanical behaviour of titanium dental
implants, a preferred choice for tooth replacement due to their superior reliability over …
implants, a preferred choice for tooth replacement due to their superior reliability over …
Semi-automated generation of bone loss defects around dental implants and its application in finite element analysis
H Jemaa, M Eisenburger, A Greuling - Computer Methods in …, 2024 - Taylor & Francis
This study aimed to develop an algorithm for modelling bone loss defects in a given
mandibular geometry, with a user-defined depth, width, place, and defect type. The …
mandibular geometry, with a user-defined depth, width, place, and defect type. The …
Evaluating the effect of functionally graded materials on bone remodeling around dental implants
Objectives This study evaluates the potential for osseointegration and remodeling of
customized dental implants made from Titanium-Hydroxyapatite Functionally Graded …
customized dental implants made from Titanium-Hydroxyapatite Functionally Graded …