[HTML][HTML] Advanced optical wavefront technologies to improve patient quality of vision and meet clinical requests

M Vacalebre, R Frison, C Corsaro, F Neri, S Conoci… - Polymers, 2022 - mdpi.com
Adaptive optics (AO) is employed for the continuous measurement and correction of ocular
aberrations. Human eye refractive errors (lower-order aberrations such as myopia and …

[HTML][HTML] Full-field Fourier ptychography (FFP): Spatially varying pupil modeling and its application for rapid field-dependent aberration metrology

P Song, S Jiang, H Zhang, X Huang, Y Zhang… - APL Photonics, 2019 - pubs.aip.org
Digital aberration measurement and removal play a prominent role in computational
imaging platforms aimed at achieving simple and compact optical arrangements. A recent …

Computational aberration compensation by coded-aperture-based correction of aberration obtained from optical Fourier coding and blur estimation

J Chung, GW Martinez, KC Lencioni, SR Sadda… - Optica, 2019 - opg.optica.org
We report a novel generalized optical measurement system and computational approach to
determine and correct aberrations in optical systems. The system consists of a …

Fourier ptychographic imaging systems, devices, and methods

G Zheng, C Yang, R Horstmeyer - US Patent 10,679,763, 2020 - Google Patents
2013-11-13 Assigned to NATIONAL INSTITUTES OF HEALTH (NIH), US DEPT. OF HEALTH
AND HUMAN SERVICES (DHHS), US GOVERNMENT reassignment NATIONAL …

Fourier ptychographic tomography

RW Horstmeyer, C Yang - US Patent 10,665,001, 2020 - Google Patents
Certain aspects pertain to Fourier ptychographic tomo graphic systems and methods for
acquiring a plurality of uniquely illuminated intensity measurements based on light passing …

Systems and methods for coded-aperture-based correction of aberration obtained from Fourier ptychography

J Chung, C Yang - US Patent 11,092,795, 2021 - Google Patents
US11092795B2 - Systems and methods for coded-aperture-based correction of aberration
obtained from Fourier ptychography - Google Patents US11092795B2 - Systems and methods …

Pupil ptychography methods and systems

J Chung, C Yang - US Patent 10,568,507, 2020 - Google Patents
10,222,605 B2 10,228,550 B2 10,401,609 B2 10,419,665 B2 2001/0055062 A1
2002/0141051 Al 2003/0116436 A1 2003/0118223 A1 2004/0057094 A1 2004/0146196 A1 …

Extreme ultraviolet microscope characterization using photomask surface roughness

G Gunjala, A Wojdyla, S Sherwin, A Shanker… - Scientific reports, 2020 - nature.com
We demonstrate a method for characterizing the field-dependent aberrations of a full-field
synchrotron-based extreme ultraviolet microscope. The statistical uniformity of the inherent …

Large dynamic range autorefraction with a low-cost diffuser wavefront sensor

GN McKay, F Mahmood, NJ Durr - Biomedical Optics Express, 2019 - opg.optica.org
Wavefront sensing with a thin diffuser has emerged as a potential low-cost alternative to a
lenslet array for aberrometry. Here we show that displacement of caustic patterns can be …

Fourier space aberration correction for high resolution refractive index imaging using incoherent light

Y Chung, H Hugonnet, SM Hong, YK Park - Optics Express, 2024 - opg.optica.org
An aberration correction method is introduced for 3D phase deconvolution microscopy. Our
technique capitalizes on multiple illumination patterns to iteratively extract Fourier space …