Real-time liver tracking algorithm based on LSTM and SVR networks for use in surface-guided radiation therapy

G Wang, Z Li, G Li, G Dai, Q **ao, L Bai, Y He, Y Liu… - Radiation …, 2021 - Springer
Background Surface-guided radiation therapy can be used to continuously monitor a
patient's surface motions during radiotherapy by a non-irradiating, noninvasive optical …

Accuracy of real-time respiratory motion tracking and time delay of gating radiotherapy based on optical surface imaging technique

L Chen, S Bai, G Li, Z Li, Q **ao, L Bai, C Li, L **an… - Radiation …, 2020 - Springer
Background Surface-guided radiation therapy (SGRT) employs a non-invasive real-time
optical surface imaging (OSI) technique for patient surface motion monitoring during …

A simple method to measure the gating latencies in photon and proton based radiotherapy using a scintillating crystal

ES Worm, JB Thomsen, JG Johansen… - Medical …, 2023 - Wiley Online Library
Background In respiratory gated radiotherapy, low latency between target motion into and
out of the gating window and actual beam‐on and beam‐off is crucial for the treatment …

High temporal resolution characterization of gating response time

RD Wiersma, BP McCabe, AH Belcher… - Medical …, 2016 - Wiley Online Library
Purpose: Low temporal latency between a gating ON/OFF signal and the LINAC beam
ON/OFF during respiratory gating is critical for patient safety. Here the authors describe a …

Technical report: TG‐142 compliant and comprehensive quality assurance tests for respiratory gating

K Woods, Y Rong - Medical physics, 2015 - Wiley Online Library
Purpose: To develop and establish a comprehensive gating commissioning and quality
assurance procedure in compliance with TG‐142. Methods: Eight Varian TrueBeam Linacs …

Geometric and dosimetric verification of a recurrent neural network algorithm to compensate for respiratory motion using an articulated robotic couch

M Lee, MS Cho, H Lee, C Jeong, J Kwak… - Journal of the Korean …, 2021 - Springer
The purpose of this study is to evaluate the performance of a recurrent neural network (RNN)-
based prediction algorithm to compensate for respiratory movement using an articulated …

Quality assurance of gating response times for surface guided motion management treatment delivery using an electronic portal imaging detector

G Barfield, EW Burton, J Stoddart… - Physics in Medicine …, 2019 - iopscience.iop.org
Gating response times of monitoring system/LINAC combinations for gated radiotherapy
treatments are notoriously difficult to measure. This difficulty may reflect why the …

System requirements to improve adaptive 4-dimensional computed tomography (4D CT) imaging

N Morton, R O'Brien, P Keall… - Biomedical Physics & …, 2022 - iopscience.iop.org
Abstract Four-Dimensional Computed Tomography (4D CT) is of increasing importance in
stereotactic body radiotherapy (SBRT) treatments affected by respiratory motion. However …

Efficient EPID‐based quality assurance of beam time delay for respiratory‐gated radiotherapy with validation on Catalyst™ and AlignRT™ systems

K Yao, M Wang, Y Du, J Liu, Q Wang… - Journal of Applied …, 2024 - Wiley Online Library
Purpose To propose a straightforward and time‐efficient quality assurance (QA) approach of
beam time delay for respiratory‐gated radiotherapy and validate the proposed method on …

Comprehensive beam delivery latency evaluation for gated proton therapy system using customized multi‐channel signal acquisition platform

Z Liu, L Pan, T Ma, HM Lu… - Journal of Applied Clinical …, 2024 - Wiley Online Library
Purpose Beam delivery latency in respiratory‐gated particle therapy systems is a crucial
issue to dose delivery accuracy. The aim of this study is to develop a multi‐channel signal …