Scientific reviews: high-resolution fourier diffraction at the IBR-2 reactor

AM Balagurov - Neutron News, 2005 - Taylor & Francis
High-resolution time-of-flight (TOF) diffractometers at short-pulse spallation neutron sources
(SPS)—the most well-known example is HRPD at ISIS—have proved themselves to be …

Neutron Fourier diffractometer FSD for residual stress studies in materials and industrial components

GD Bokuchava, AM Balagurov, VV Sumin… - Journal of Surface …, 2010 - Springer
Neutron diffraction study of residual stresses in materials became widely used in the world
due to high penetrating power of neutrons. Therefore, to study residual stresses, the FSD …

A Monte Carlo Model of the Neutron Detector Based on Lithium-Glass Scintillator

ES Kuzmin, GD Bokuchava, IY Zimin… - Instruments and …, 2021 - Springer
A Monte Carlo model of the thermal-neutron scintillation detector based on NE 912 lithium
glass has been created and verified. The simulation was validated by comparing its result to …

Phase errors and their influence on the RTOF-Fourier method

VA Kudryashev, HG Priesmeyer, JM Keuter… - Nuclear Instruments and …, 1995 - Elsevier
The influence of phase errors on the accuracy of the neutron diffraction peak parameters is
discussed. It is shown that a constant phase error leads to both a distortion of the shape and …

НЕЙТРОННЫЙ ФУРЬE-ДИФРАКТОМЕТР ФСД ДЛЯ ИССЛЕДОВАНИЯ ОСТАТОЧНЫХ НАПРЯЖЕНИЙ В МАТЕРИАЛАХ И ПРОМЫШЛЕННЫХ ИЗДЕЛИЯХ

ГД Бокучава, AM Балагуров, ВВ Сумин… - Поверхность …, 2010 - elibrary.ru
Изучение остаточных напряжений в материалах при помощи дифракции нейтронов
приобрело широкое распространение в мире из-за высокой проникающей способности …

A USB-based data acquisition system for neutron TOF measurements

MI Khalil - Measurement Science and Technology, 2005 - iopscience.iop.org
A universal serial bus (USB)-based data acquisition system for neutron time-of-flight (TOF)
spectrum measurements is designed and tested at the Cairo Fourier diffractometer facility …

Assessment and main characteristic parameters of the Cairo Fourier diffractometer facility

RMA Maayouf, I Abdel-Latif, A El-Kady… - Nuclear Instruments and …, 1997 - Elsevier
This report represents the results of the measurements performed recently with the Cairo
Fourier diffractometer facility (CFDF). The CFDF performance is assessed and the main …

CFDF—a new Fourier RTOF-diffractometer for stress and powder diffraction investigations

RMA Maayouf, IA Abdel-Latif, ASI El-Kady… - Journal of Neutron …, 1998 - Taylor & Francis
The present work deals with the results of measurements performed recently with the Cairo
Fourier diffractometer facility (CFDF). The CFDF is based on the reverse time-of-flight …

New development for the reverse time of flight analysis of spectra measured using Fourier Diffractometer Facilities

RMA Maayouf, MI Khalil - Nuclear Instruments and Methods in Physics …, 2002 - Elsevier
The present work introduces a new design to replace the (Finnish make) reverse time of
flight (RTOF) analyzer used for the Fourier diffractometer facilities. The new design applies a …

Neural network based fault diagnosis procedure for the detector system of CFDF

MI Khalil - Journal of Computer Science & Technology, 2010 - sedici.unlp.edu.ar
This paper outlines and deals with the problem of fault detection, isolation and identification
of the four-elements detector system attached to the Cairo Fourier diffractometer facility …