Modeling and stability analysis of $ LCL $-type grid-connected inverters: A comprehensive overview
Due to the advantages of superior harmonics attenuation ability and reduced size, the LCL
filter has been widely adopted to interface between the inverter and the grid for improving …
filter has been widely adopted to interface between the inverter and the grid for improving …
[HTML][HTML] Analysis and mitigation of harmonic resonances in multi–parallel grid–connected inverters: A review
R Ali, T O'Donnell - Energies, 2022 - mdpi.com
With the move towards decarbonization of the energy system and increased use of
renewable generation, the number of power electronics converter interfaced resources …
renewable generation, the number of power electronics converter interfaced resources …
Analysis and comparison of notch filter and capacitor voltage feedforward active dam** techniques for LCL grid-connected converters
E Rodriguez-Diaz, FD Freijedo… - … on Power Electronics, 2018 - ieeexplore.ieee.org
The use of LCL filters is a well-accepted solution to attenuate the harmonics created by the
pulsewidth modulation. However, inherently LCL filters have a resonance region where the …
pulsewidth modulation. However, inherently LCL filters have a resonance region where the …
Phase Resha** via All-Pass Filters for Robust LCL-Filter Active Dam**
Active dam** is a common way to stabilize the current control of LCL-filtered converters. In
this paper, the stable region of-180° phase crossing is first identified within a predefined …
this paper, the stable region of-180° phase crossing is first identified within a predefined …
A Hybrid Multiresonances Suppression Method for Nonsynchronous LCL-Type Grid-Connected Inverter Clusters Under Weak Grid
J Liu, X Sun, Z Chen, Y Chi, W Song… - … on Power Electronics, 2024 - ieeexplore.ieee.org
Multiresonance phenomena occur in inverter clusters under weak grid, with more complex
resonance characteristics. Traditional suppression methods are difficult to determine control …
resonance characteristics. Traditional suppression methods are difficult to determine control …
On the stability of advanced power electronic converters: The generalized bode criterion
D Lumbreras, EL Barrios, A Urtasun… - … on Power Electronics, 2018 - ieeexplore.ieee.org
A key factor in the design of power electronic converters is the development of control
systems and, in particular, the determination of their stability. Due to ease of application, the …
systems and, in particular, the determination of their stability. Due to ease of application, the …
Robust H∞ Active Dam** Filter with Preserved Resonant Peak for Resonant Harmonic Suppression
S Chen, Y Ye - IEEE Journal of Emerging and Selected Topics …, 2024 - ieeexplore.ieee.org
Filter-based active dam** (AD) without additional sensors has been widely used in LCL-
type grid-tied inverters. For the resonance problem of the LCL filter, the AD filter is devised …
type grid-tied inverters. For the resonance problem of the LCL filter, the AD filter is devised …
[HTML][HTML] 2DOF-based current controller for single-phase grid-connected voltage source inverter applications
FJ López-Alcolea, EJ Molina-Martínez, AP Torres… - Applied Energy, 2023 - Elsevier
This paper presents the design of a discrete-time control scheme for the current injected into
the grid by a single-phase voltage source inverter (VSI). The VSI is connected to the grid by …
the grid by a single-phase voltage source inverter (VSI). The VSI is connected to the grid by …
A novel sliding mode observer-based compound sliding mode current control with active dam** for single phase grid-tied inverter system in weak grid
Q Teng, G Xu, X Zheng, H Mai, X Ma, Y Wang - International Journal of …, 2022 - Elsevier
This paper proposes a novel sliding mode observer (SMO)-based compound sliding mode
current control (CSMCC) strategy with active dam** for the single-phase grid-tied inverter …
current control (CSMCC) strategy with active dam** for the single-phase grid-tied inverter …
A general graphical method for filter-based active dam**: Evaluation, exploration, and design
C Wang, D Pan, X Wang, Y He, H Zhang… - IEEE Journal of …, 2022 - ieeexplore.ieee.org
Filter-based active dam** is a promising solution to tackle the resonance hazard of LCL-
filtered inverters. Although various methods have been developed, it still lacks guidelines to …
filtered inverters. Although various methods have been developed, it still lacks guidelines to …