Radiation dose and fluoroscopy time of modern endovascular treatment techniques in patients with saccular unruptured intracranial aneurysms

R Forbrig, Y Ozpeynirci, M Grasser, F Dorn, T Liebig… - European …, 2020 - Springer
Objectives Modern endovascular treatment of unruptured intracranial aneurysms (UIAs)
demands for observance of diagnostic reference levels (DRLs). The national DRL (250 Gy …

Proposed achievable levels of dose and impact of dose-reduction systems for thrombectomy in acute ischemic stroke: an international, multicentric, retrospective study …

A Guenego, PJ Mosimann, VM Pereira, P Nicholson… - European …, 2019 - Springer
Background International dose reference levels are lacking for mechanical thrombectomy in
acute ischemic stroke patients with large vessel occlusions. We studied whether radiation …

Radiation exposure and fluoroscopy time in mechanical thrombectomy of anterior circulation ischemic stroke depending on the interventionalist's experience—a …

CS Weyland, F Hemmerich, MA Möhlenbruch… - European …, 2020 - Springer
Purpose To quantify the influence of interventionalist's experience on procedure time,
radiation exposure, and fluoroscopy time during mechanical thrombectomy (MT) in the …

Mechanical thrombectomy practices in France: Exhaustive survey of centers and individual operators

G Forestier, B Kerleroux, K Janot, F Zhu… - Journal of …, 2020 - Elsevier
Background and purpose Mechanical thrombectomy (MT) has dramatically changed the
landscape of stroke care as well as stroke care organization. Public health institutions are …

Mortality after mechanical thrombectomy in anterior circulation stroke may be higher at nighttime and on weekends

C Zaeske, L Goertz, J Kottlors, M Schlamann… - European …, 2021 - Springer
Objectives The objective of this study was to compare clinical outcome and procedural
differences of mechanical thrombectomy (MT) during on-call with regular operating hours …

Neurointerventions on two generations of angiography systems: Recent systems reduce radiation exposure by half

X Li, K Yang, TA Marschall, MM Rehani, B Liu - Physica Medica, 2024 - Elsevier
Purpose Fluoroscopically-guided neurointervention may be associated with prolonged
procedure time and substantial radiation exposure to the patient and staff. This study sought …

Occlusion type, number of recanalization passages and dose program determine radiation dose in endovascular stroke thrombectomy

G Peter, V Hesselmann, M Ilnicki, T Illies… - Clinical …, 2022 - Springer
Purpose Identification of independent treatment factors associated with high radiation
exposure during endovascular mechanical thrombectomy (EMT) in acute ischemic stroke …

Radiation dose and fluoroscopy time of endovascular treatment in patients with intracranial lateral dural arteriovenous fistulae

R Forbrig, R Stahl, LL Geyer, Y Ozpeynirci… - Clinical …, 2021 - Springer
Purpose Intracranial lateral dural arteriovenous fistula (LDAVF) represents a specific
subtype of cerebrovascular fistulae, harboring a potentially life-threatening risk of brain …

Radiation exposure per thrombectomy attempt in modern endovascular stroke treatment in the anterior circulation

CS Weyland, F Seker, A Potreck, C Hametner… - European …, 2020 - Springer
Objective To quantify radiation exposure (RE) of endovascular stroke treatment (EST) in the
anterior circulation per thrombectomy attempt and determine causes for interventions …

Dosimetric indices in fluoroscopically guided cerebral intervention procedure and complexity index: a multicenter study

M Cavallari, L D'Ercole, S Zucca, N Paruccini… - The European Physical …, 2024 - Springer
Patient dose in fluoroscopically guided procedures is strongly related to procedure
complexity. This Italian multicentric study aims to establish relationship between clinical …