[HTML][HTML] Aspartate aminotransferase (AST/GOT) and alanine aminotransferase (ALT/GPT) detection techniques

XJ Huang, YK Choi, HS Im, O Yarimaga, E Yoon… - Sensors, 2006 - mdpi.com
The levels of aspartate aminotransferase (AST/GOT) and alanine aminotransferase
(ALT/GPT) in serum can help people diagnose body tissues especially the heart and the …

Biosensors for life quality: Design, development and applications

J Castillo, S Gáspár, S Leth, M Niculescu… - Sensors and Actuators B …, 2004 - Elsevier
Biosensors, combining a selective biological recognition element and a sensitive
transducer, are versatile analytical tools applied more and more in different fields, such as …

Nanocomposite film based on graphene oxide for high performance flexible glucose biosensor

JD Qiu, J Huang, RP Liang - Sensors and Actuators B: Chemical, 2011 - Elsevier
A homogeneous chitosan–ferrocene/graphene oxide/glucose oxidase (CS–Fc/GO/GOx)
nanocomposite film was successfully constructed as a novel platform for the fabrication of …

Amperometric enzyme biosensors based on optimised electron-transfer pathways and non-manual immobilisation procedures

W Schuhmann - Reviews in Molecular Biotechnology, 2002 - Elsevier
Development of reagentless biosensors implies the tight and functional immobilisation of
biological recognition elements on transducer surfaces. Specifically, in the case of …

Polymer-based, flexible glutamate and lactate microsensors for in vivo applications

A Weltin, J Kieninger, B Enderle, AK Gellner… - Biosensors and …, 2014 - Elsevier
We present a flexible microsensor, based on a polymer substrate, for multiparametric,
electrochemical in vivo monitoring. The sensor strip with a microelectrode array at the tip …

Microdialysis of GABA and glutamate: analysis, interpretation and comparison with microsensors

M van der Zeyden, WH Oldenziel, K Rea… - Pharmacology …, 2008 - Elsevier
GABA and glutamate sampled from the brain by microdialysis do not always fulfill the classic
criteria for exocytotic release. In this regard the origin (neuronal vs. astroglial, synaptic vs …

Listening to the brain: microelectrode biosensors for neurochemicals

N Dale, S Hatz, F Tian, E Llaudet - Trends in biotechnology, 2005 - cell.com
Chemical signalling underlies every function of the nervous system, from those of which we
are unaware, for example, control of the heart, to higher cognitive functions, such as …

Real‐time monitoring of exocytotic glutamate release from single neuron by amperometry at an enzymatic biosensor

QF Qiu, FL Zhang, Y Tang, XW Zhang, H Jiang… - …, 2018 - Wiley Online Library
Glutamate (Glu) is recognized as a vital neurotransmitter released via vesicular exocytosis
and plays important roles in many physiological processes. Microelectrode amperometry …

Effects of electrolyte and pH on the behavior of cross-linked films of ferrocene-modified poly (ethylenimine)

SA Merchant, DT Glatzhofer, DW Schmidtke - Langmuir, 2007 - ACS Publications
Ferrocene redox polymers based on the coupling of ferrocenecarboxaldehyde to both linear
and branched poly (ethylenimine)(PEI) have been prepared to investigate the effects of pH …

Enzyme-based choline and L-glutamate biosensor electrodes on silicon microprobe arrays

O Frey, T Holtzman, RM McNamara… - Biosensors and …, 2010 - Elsevier
Brain-implantable microprobe arrays, 6.5 mm shaft-length, incorporating several recessed Pt
microelectrodes (50μm× 150μm) and an integrated Ag/AgCl reference electrode fabricated …