Review of sub-synchronous interaction in wind integrated power systems: classification, challenges, and mitigation techniques
Emerging sub-synchronous interactions (SSI) in wind-integrated power systems have added
intense attention after numerous incidents in the US and China due to the involvement of …
intense attention after numerous incidents in the US and China due to the involvement of …
Stability analysis on torsional interactions of turbine-generator connected with DFIG-WECS using admittance model
To evaluate the stability of Subsynchronous Torsional Interactions (SSTI), we propose a
simple and effective approach using admittance model. The proposed approach gives the …
simple and effective approach using admittance model. The proposed approach gives the …
Subsynchronous oscillation of large DFIG-based wind farms integration through MMC-based HVDC
J Lv, P Dong, G Shi, X Cai, H Rao… - … Conference on Power …, 2014 - ieeexplore.ieee.org
With rapid development of offshore wind power and modular multilevel converter-based
high-voltage DC transmission (MMC-HVDC), subsynchronous oscillation (SSO) phenomena …
high-voltage DC transmission (MMC-HVDC), subsynchronous oscillation (SSO) phenomena …
Sub-synchronous resonance dam** using high penetration PV plant
M Khayyatzadeh, R Kazemzadeh - Mechanical Systems and Signal …, 2017 - Elsevier
The growing need to the clean and renewable energy has led to the fast development of
transmission voltage-level photovoltaic (PV) plants all over the world. These large scale PV …
transmission voltage-level photovoltaic (PV) plants all over the world. These large scale PV …
Experimental validation of an active wideband SSR dam** scheme for series-compensated networks
Transmission network reinforcements are being undertaken to meet renewable energy
targets toward a low carbon transition. High-voltage direct-current (HVDC) links and series …
targets toward a low carbon transition. High-voltage direct-current (HVDC) links and series …
Online evaluation of turbo-generator shaft fatigue damage caused by subsynchronous oscillation
D Chen, Y Zhang, Y Gu - IEEE Access, 2020 - ieeexplore.ieee.org
Subsynchronous oscillation (SSO) fault can cause torsional vibration and fatigue damage of
the shafting system, thereby endanger the safe operation of the turbo-generator set. A novel …
the shafting system, thereby endanger the safe operation of the turbo-generator set. A novel …
An approach on nonlinear integration of MMC to linear model of ROPS in transient analysis
The modular multilevel converter (MMC) is a novel prospective multilevel converter topology
for high‐voltage or high‐power applications. This paper presents the 3‐Φ model integrated …
for high‐voltage or high‐power applications. This paper presents the 3‐Φ model integrated …
ADRC-based control strategies to alleviate SSR using STATCOM
Increasing prominence of series compensation into the power system has evidently
enhanced the rise of subsynchronous resonance (SSR). Alleviation of SSR with two novel …
enhanced the rise of subsynchronous resonance (SSR). Alleviation of SSR with two novel …
Design of decoupled current controller for back to back modular multilevel converter based HVDC transmission system
The modular multilevel converter (MMC) is becoming utmost successful in-recent multilevel
configurations, particularly for medium and high voltage applications. A typical application of …
configurations, particularly for medium and high voltage applications. A typical application of …
[PDF][PDF] Design of decoupled current controller for grid connected modular multilevel converter
Modular multilevel converter (MMC) becomes furthermost promising topologies especially
for medium or high voltage (HV) applications. A typical application of MMC is to control the …