Developments in the field of conducting and non-conducting polymer based potentiometric membrane sensors for ions over the past decade
Many research studies have been conducted on the use of conjugated polymers in the
construction of chemical sensors including potentiometric, conductometric and …
construction of chemical sensors including potentiometric, conductometric and …
One decade of research on ion-selective electrodes in Iran (1996–2006)
This review presents a general overview about the development of ion-selective electrodes
in Iran during the past decade (1996–2006). All of the reported ion-selective sensors (for …
in Iran during the past decade (1996–2006). All of the reported ion-selective sensors (for …
The fabrication of potentiometric membrane sensors and their applications
Ionophore-incorporated PVC-membrane sensors are well-established analytical tools
routinely used for the selective and direct measurement of a wide variety of different ions in …
routinely used for the selective and direct measurement of a wide variety of different ions in …
Determination of gadolinium (III) ions in soil and sediment samples by a novel gadolinium membrane sensor based on 6-methyl-4-{[1-(2-thienyl) methylidene] amino} …
Highly selective and sensitive poly (vinyl chloride)(PVC) membrane electrodes based on 6-
methyl-4-{[1-(2-thienyl) methylidene] amino} 3-thioxo-3, 4-dihydro-1, 2, 4-triazin-5-(2H)-one …
methyl-4-{[1-(2-thienyl) methylidene] amino} 3-thioxo-3, 4-dihydro-1, 2, 4-triazin-5-(2H)-one …
Application of Novel Praseodymium (III) PVC‐Membrane Electrode for Determination of Pr (III) Ions in Soil and Sediment Samples
A novel Pr (III) ion‐selective polyvinyl chloride (PVC) membrane sensor, based on N, N‐bis
(α‐methylsalicylidene) diethylenetriamine (BMT) as a new ionophore, has been prepared …
(α‐methylsalicylidene) diethylenetriamine (BMT) as a new ionophore, has been prepared …
Determination of terbium (III) ions in phosphate rock samples by a Tb3+–PVC membrane sensor based on N, N-Dimethyl-N′, N ″-bis (4-methoxyphenyl) …
A poly (vinyl chloride)-based membrane of N, N-Dimethyl-N′, N ″-bis (4-methoxyphenyl)
phosphoramidate (DMP) as a neutral carrier was prepared and investigated as a Tb3+ …
phosphoramidate (DMP) as a neutral carrier was prepared and investigated as a Tb3+ …
Lanthanide recognition: An asymetric erbium microsensor based on a hydrazone derivative
N'-(2-hydroxy-1, 2-diphenylethylidene) benzohydrazide (HDB) was found to have a very
selective and sensitive behavior towards erbium (III) ions, in comparison to thirteen …
selective and sensitive behavior towards erbium (III) ions, in comparison to thirteen …
Cobalt (II) ion detection in electroplating wastewater by a new cobalt ion-selective electrode based on N′-[1-(2-thienyl) ethylidene]-2-furohydrazide
An authentic PVC membrane cobalt (II) ion-selective electrode has been constructed in this
research, using N′-[1-(2-thienyl) ethylidene]-2-furohydrazide (NTEF) as membrane carrier …
research, using N′-[1-(2-thienyl) ethylidene]-2-furohydrazide (NTEF) as membrane carrier …
A novel iron (III)-PVC membrane potentiomeric sensor based on N-(2-hydroxyethyl) ethylenediamine-N, N', N"-triacetic acid
HA Zamani, MT Hamed-Mosavian, E Hamidfar… - Materials Science and …, 2008 - Elsevier
This work introduces a unique ionophore for the selective determination of Fe (III) ions. This
ionophore was N-(2-hydroxyethyl) ethylenediamine-N, N′, N ″-triacetic acid (NTA) …
ionophore was N-(2-hydroxyethyl) ethylenediamine-N, N′, N ″-triacetic acid (NTA) …
A novel sensor for the selective monitoring of trace ytterbium ions using an agarose-based optical membrane
A novel highly selective sensitive optical sensor was prepared via the chemical
immobilization of β-2-hydroxybenzyl-5-bromo-2-hydroxyazastyrene (HBBHAS) on an epoxy …
immobilization of β-2-hydroxybenzyl-5-bromo-2-hydroxyazastyrene (HBBHAS) on an epoxy …