Developments in the field of conducting and non-conducting polymer based potentiometric membrane sensors for ions over the past decade

F Faridbod, MR Ganjali, R Dinarvand, P Norouzi - Sensors, 2008 - mdpi.com
Many research studies have been conducted on the use of conjugated polymers in the
construction of chemical sensors including potentiometric, conductometric and …

One decade of research on ion-selective electrodes in Iran (1996–2006)

MR Ganjali, P Norouzi, F Faridbod, M Rezapour… - Journal of the Iranian …, 2007 - Springer
This review presents a general overview about the development of ion-selective electrodes
in Iran during the past decade (1996–2006). All of the reported ion-selective sensors (for …

The fabrication of potentiometric membrane sensors and their applications

F Faridbod, MR Ganjali, R Dinarvand… - African Journal of …, 2007 - ajol.info
Ionophore-incorporated PVC-membrane sensors are well-established analytical tools
routinely used for the selective and direct measurement of a wide variety of different ions in …

Determination of gadolinium (III) ions in soil and sediment samples by a novel gadolinium membrane sensor based on 6-methyl-4-{[1-(2-thienyl) methylidene] amino} …

HA Zamani, G Rajabzadeh, MR Ganjali, P Norouzi - Analytica chimica acta, 2007 - Elsevier
Highly selective and sensitive poly (vinyl chloride)(PVC) membrane electrodes based on 6-
methyl-4-{[1-(2-thienyl) methylidene] amino} 3-thioxo-3, 4-dihydro-1, 2, 4-triazin-5-(2H)-one …

Application of Novel Praseodymium (III) PVC‐Membrane Electrode for Determination of Pr (III) Ions in Soil and Sediment Samples

HA Zamani, MR Ganjali, P Norouzi, S Meghdadi - Analytical letters, 2008 - Taylor & Francis
A novel Pr (III) ion‐selective polyvinyl chloride (PVC) membrane sensor, based on N, N‐bis
(α‐methylsalicylidene) diethylenetriamine (BMT) as a new ionophore, has been prepared …

Determination of terbium (III) ions in phosphate rock samples by a Tb3+–PVC membrane sensor based on N, N-Dimethyl-N′, N ″-bis (4-methoxyphenyl) …

HA Zamani, MR Ganjali, P Norouzi, A Tadjarodi… - Materials Science and …, 2008 - Elsevier
A poly (vinyl chloride)-based membrane of N, N-Dimethyl-N′, N ″-bis (4-methoxyphenyl)
phosphoramidate (DMP) as a neutral carrier was prepared and investigated as a Tb3+ …

Lanthanide recognition: An asymetric erbium microsensor based on a hydrazone derivative

F Faridbod, MR Ganjali, B Larijani, P Norouzi, S Riahi… - Sensors, 2007 - mdpi.com
N'-(2-hydroxy-1, 2-diphenylethylidene) benzohydrazide (HDB) was found to have a very
selective and sensitive behavior towards erbium (III) ions, in comparison to thirteen …

Cobalt (II) ion detection in electroplating wastewater by a new cobalt ion-selective electrode based on N′-[1-(2-thienyl) ethylidene]-2-furohydrazide

HA Zamani, MR Ganjali, P Norouzi, M Adib - Sensor Letters, 2007 - ingentaconnect.com
An authentic PVC membrane cobalt (II) ion-selective electrode has been constructed in this
research, using N′-[1-(2-thienyl) ethylidene]-2-furohydrazide (NTEF) as membrane carrier …

A novel iron (III)-PVC membrane potentiomeric sensor based on N-(2-hydroxyethyl) ethylenediamine-N, N', N"-triacetic acid

HA Zamani, MT Hamed-Mosavian, E Hamidfar… - Materials Science and …, 2008 - Elsevier
This work introduces a unique ionophore for the selective determination of Fe (III) ions. This
ionophore was N-(2-hydroxyethyl) ethylenediamine-N, N′, N ″-triacetic acid (NTA) …

A novel sensor for the selective monitoring of trace ytterbium ions using an agarose-based optical membrane

AS Amin, HH El-Feky, N Hassan - RSC advances, 2022 - pubs.rsc.org
A novel highly selective sensitive optical sensor was prepared via the chemical
immobilization of β-2-hydroxybenzyl-5-bromo-2-hydroxyazastyrene (HBBHAS) on an epoxy …