Bulk material interrogation experimental results and validation with Geant4 for replacement of dangerous radiological sources in oil-well logging industries
Abstract The Kansas State University Materials Interrogation (KSUMI) test facility was set up
to enable bulk-material irradiation experiments that replicate similar oil-well logging …
to enable bulk-material irradiation experiments that replicate similar oil-well logging …
Assessment of gamma-rays generated by the spontaneous fission source 252Cf using a Monte Carlo method
R Khabaz - Annals of Nuclear Energy, 2012 - Elsevier
This paper represents the evaluation of the gamma-ray spectrum associated with the 252Cf
spontaneous fission source, based on Monte Carlo simulation. In this study, with the help of …
spontaneous fission source, based on Monte Carlo simulation. In this study, with the help of …
The effect of the housing material on the NaI (Tl) detector response function
In this study, a Monte Carlo program has been developed to simulate the response function
of the NaI (Tl) detector with all features for 60 Co and 137 Cs and to investigate the effects of …
of the NaI (Tl) detector with all features for 60 Co and 137 Cs and to investigate the effects of …
Systematic assessment of neutron and gamma backgrounds relevant to operational modeling and detection technology implementation
DE Archer, DE Hornback, JO Johnson, AD Nicholson… - 2015 - osti.gov
This report summarizes the findings of a two year effort to systematically assess neutron and
gamma backgrounds relevant to operational modeling and detection technology …
gamma backgrounds relevant to operational modeling and detection technology …
Design and experiment of dual-energy X-ray material recognition using a 950 keV X-band Linac
K Lee, E Hashimoto, T Yamamoto, T Natsui… - Nuclear Instruments and …, 2011 - Elsevier
The 950keV portable X-band (9.4 GHz) linear accelerator (Linac) provides on-site high-
energy X-ray inspection, including material recognition up to a certain precision. We have …
energy X-ray inspection, including material recognition up to a certain precision. We have …
Improving the sensitivity of fast neutron inelastic scatter analysis to iron using associated particle collimation
MR Abel, LH Nie - Nuclear Instruments and Methods in Physics Research …, 2019 - Elsevier
Purpose The purpose of this study is twofold; first, a prompt gamma-ray neutron activation
analysis (PGNAA) system will be constructed and employed in order to find the approximate …
analysis (PGNAA) system will be constructed and employed in order to find the approximate …
Design and fabrication of an in situ gamma radioactivity measurement system for marine environment and its calibration with Monte Carlo method
H Abdollahnejad, N Vosoughi, MR Zare - Applied Radiation and Isotopes, 2016 - Elsevier
Simulation, design and fabrication of a sealing enclosure is carried out for a NaI (Tl) 2 ″× 2
″detector, to be used as in situ gamma radioactivity measurement system in marine …
″detector, to be used as in situ gamma radioactivity measurement system in marine …
[CITATION][C] Viability Study of Gamma Emission Tomography for Spent Fuel Verification: JNT 1955 Phase I Technical Report
EL Smith - 2016
Develo** an Energy Resolution Model for Monte Carlo-Based SPECT Simulation and Reconstruction Using a GE Discovery NM/CT 670 Pro System
A Andelin - 2024 - gupea.ub.gu.se
Aim: In order to apply Monte Carlo (MC)-based algorithms for simulations of gamma camera
acquisitions, the intrinsic characteristics of the system must be properly defined. This study …
acquisitions, the intrinsic characteristics of the system must be properly defined. This study …
Associated Particle Neutron Elemental Imaging for Noninvasive Medical Diagnostics
MR Abel - 2019 - search.proquest.com
A novel system has been simulated with accompanying experimental data that is designed
to provide spatial information of elemental concentrations at biologically relevant levels …
to provide spatial information of elemental concentrations at biologically relevant levels …