Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
Medical applications of synchrotron radiation
P Suortti, W Thomlinson - Physics in Medicine & Biology, 2003 - iopscience.iop.org
The medical imaging and therapeutic technologies that are based on the use of radiation
are reviewed briefly, with special emphasis on the recent developments of synchrotron …
are reviewed briefly, with special emphasis on the recent developments of synchrotron …
Effects of pulsed, spatially fractionated, microscopic synchrotron X-ray beams on normal and tumoral brain tissue
E Bräuer-Krisch, R Serduc, EA Siegbahn… - … Research/Reviews in …, 2010 - Elsevier
Microbeam radiation therapy (MRT) uses highly collimated, quasi-parallel arrays of X-ray
microbeams of 50–600keV, produced by third generation synchrotron sources, such as the …
microbeams of 50–600keV, produced by third generation synchrotron sources, such as the …
Response of rat intracranial 9L gliosarcoma to microbeam radiation therapy
Radiotherapeutic doses for malignant gliomas are generally palliative because greater,
supposedly curative doses would impart clinically unacceptable damage to nearby vital …
supposedly curative doses would impart clinically unacceptable damage to nearby vital …
Interlaced x-ray microplanar beams: a radiosurgery approach with clinical potential
FA Dilmanian, Z Zhong, T Bacarian… - Proceedings of the …, 2006 - pnas.org
Studies have shown that x-rays delivered as arrays of parallel microplanar beams
(microbeams), 25-to 90-μm thick and spaced 100–300 μm on-center, respectively, spare …
(microbeams), 25-to 90-μm thick and spaced 100–300 μm on-center, respectively, spare …
[HTML][HTML] Microbeam radiation therapy: Clinical perspectives
Microbeam radiation therapy (MRT), a novel form of spatially fractionated radiotherapy (RT),
uses arrays of synchrotron-generated X-ray microbeams (MB). MRT has been identified as a …
uses arrays of synchrotron-generated X-ray microbeams (MB). MRT has been identified as a …
Radiochromic film dosimetry
CG Soares - Radiation measurements, 2006 - Elsevier
The object of this paper is to give a new user some practical information on the use of
radiochromic films for medical applications. While various aspects of radiochromic film …
radiochromic films for medical applications. While various aspects of radiochromic film …
FLASH and minibeams in radiation therapy: the effect of microstructures on time and space and their potential application to protontherapy
A Mazal, Y Prezado, C Ares, L de Marzi… - The British Journal of …, 2020 - academic.oup.com
After years of lethargy, studies on two non-conventional microstructures in time and space of
the beams used in radiation therapy are enjoying a huge revival. The first effect called …
the beams used in radiation therapy are enjoying a huge revival. The first effect called …
Weanling piglet cerebellum: a surrogate for tolerance to MRT (microbeam radiation therapy) in pediatric neuro-oncology
JA Laissue, H Blattmann, M Di Michiel… - … and Applications III, 2001 - spiedigitallibrary.org
The cerebellum of the weanling piglet (Yorkshire) was used as a surrogate for the
radiosensitive human infant cerebellum in a Swiss-led program of experimental microbeam …
radiosensitive human infant cerebellum in a Swiss-led program of experimental microbeam …
[HTML][HTML] Effects of microbeam radiation therapy on normal and tumoral blood vessels
Microbeam radiation therapy (MRT) is a new form of preclinical radiotherapy using quasi-
parallel arrays of synchrotron X-ray microbeams. While the deposition of several hundred …
parallel arrays of synchrotron X-ray microbeams. While the deposition of several hundred …
In vivo two-photon microscopy study of short-term effects of microbeam irradiation on normal mouse brain microvasculature
R Serduc, P Vérant, JC Vial, R Farion, L Rocas… - International Journal of …, 2006 - Elsevier
Purpose: The purpose of this study was to assess the early effects of microbeam irradiation
on the vascular permeability and volume in the parietal cortex of normal nude mice using …
on the vascular permeability and volume in the parietal cortex of normal nude mice using …