Finite element analysis in the optimization of posterior-stabilized total knee arthroplasty
L Dagneaux, F Canovas, F Jourdan - Orthopaedics & Traumatology …, 2024 - Elsevier
Posterior-stabilized total knee arthroplasty (PS-TKA) is associated with high rates of
satisfaction and functional recovery. This is notably attributed to implant optimization in terms …
satisfaction and functional recovery. This is notably attributed to implant optimization in terms …
A multimodal assessment of cementless tibial baseplate fixation using radiography, radiostereometric analysis, and magnetic resonance imaging
Fixation in cementless total knee arthroplasty is provided by osseous integration.
Radiography, radiostereometric analysis (RSA), and magnetic resonance imaging (MRI) …
Radiography, radiostereometric analysis (RSA), and magnetic resonance imaging (MRI) …
[HTML][HTML] The effect of coating characteristics on implant-bone interface mechanics
E Sánchez, E de Vries, D Matthews… - Journal of …, 2024 - Elsevier
Successful osseointegration of press-fit implants depends on the initial stability, often
measured by the micromotions between the implant and bone. A good primary stability can …
measured by the micromotions between the implant and bone. A good primary stability can …
An Anterior Spike Decreases Bone-Implant Micromotion in Cementless Tibial Baseplates for Total Knee Arthroplasty: A Biomechanical Study
Background Cementless tibial baseplates in total knee arthroplasty include fixation features
(eg, pegs, spikes, and keels) to ensure sufficient primary bone-implant stability. While the …
(eg, pegs, spikes, and keels) to ensure sufficient primary bone-implant stability. While the …
Drivers of initial stability in cementless TKA: Isolating effects of tibiofemoral conformity and fixation features
The initial fixation of cementless tibial trays after total knee arthroplasty is critical to ensure
bony ingrowth and long-term fixation. Various fixed-bearing implant designs that utilize …
bony ingrowth and long-term fixation. Various fixed-bearing implant designs that utilize …
Axial and sagittal rotation of cementless tibial baseplates occurs in bone under joint loading
Background There has been a recent increase in the use of cementless fixation for primary
total knee arthroplasty. While the early results of contemporary cementless implants are …
total knee arthroplasty. While the early results of contemporary cementless implants are …
Is Tibial Bone Mineral Density Related to Sex, Age, Preoperative Alignment, or Fixation Method in Primary Total Knee Arthroplasty?
TM Borsinger, FJQ Gonzalez, CA Pagan… - The Journal of …, 2024 - Elsevier
Background Cementless total knee arthroplasty (TKA) has regained interest for its potential
for long-term biologic fixation. The density of the bone is related to its ability to resist static …
for long-term biologic fixation. The density of the bone is related to its ability to resist static …
Impact of Surgical Alignment, Bone Properties, Anterior–Posterior Translation, and Implant Design Factors on Fixation in Cementless Unicompartmental Knee …
Micromotion exceeding 150 μm at the implant–bone interface may prevent bone formation
and limit fixation after cementless knee arthroplasty. Understanding the critical parameters …
and limit fixation after cementless knee arthroplasty. Understanding the critical parameters …
[HTML][HTML] A Modified Wagner Stem Design Increases the Primary Stability in Cementless Revision Hip Arthroplasty
Background Primary stability is of great importance for the longevity of the implant in
cementless revision total hip arthroplasty, since instability is a major cause of rerevision. The …
cementless revision total hip arthroplasty, since instability is a major cause of rerevision. The …
Optimisation des prothèses totales de genou postéro-stabilisées par la méthode des éléments finis
L Dagneaux, F Canovas, F Jourdan - Revue de Chirurgie Orthopédique et …, 2023 - Elsevier
Résumé La prothèse totale de genou (PTG) postéro-stabilisée (PS) est associée à un haut
niveau de satisfaction et de retour fonctionnel des patients, ces résultats étant notamment …
niveau de satisfaction et de retour fonctionnel des patients, ces résultats étant notamment …