A differential sequence component protection scheme for microgrids with inverter-based distributed generators
E Casagrande, WL Woon, HH Zeineldin… - … on smart grid, 2013 - ieeexplore.ieee.org
The protection of a microgrid containing inverter-based distributed generators (IBDGs)
presents several problems if traditional techniques which rely on the current (fuses and …
presents several problems if traditional techniques which rely on the current (fuses and …
Speed of line protection-can we break free of phasor limitations?
EO Schweitzer, B Kasztenny, A Guzmán… - 2015 68th Annual …, 2015 - ieeexplore.ieee.org
Today's relays are predominantly based on phasors, and as such, they incur a delay
associated with the full-cycle observation window required for accurate phasor estimation …
associated with the full-cycle observation window required for accurate phasor estimation …
Adaptive current differential protection schemes for transmission-line protection
Throughout the history of power system protection, researchers have strived to increase
sensitivity and speed of apparatus protection systems without compromising security. With …
sensitivity and speed of apparatus protection systems without compromising security. With …
A novel phaselet-based approach for islanding detection in inverter-based distributed generation systems
AT Kolli, N Ghaffarzadeh - Electric Power Systems Research, 2020 - Elsevier
In this paper, a novel signal processing approach based on phaselet algorithm is proposed
to detect the islanding phenomenon. Phaselets can effectively compute the phasors over …
to detect the islanding phenomenon. Phaselets can effectively compute the phasors over …
Tutorial on operating characteristics of microprocessor-based multiterminal line current differential relays
B Kasztenny, G Benmouyal, HJ Altuve… - Present Problems of …, 2013 - yadda.icm.edu.pl
The current differential principle is the most powerful short-circuit protection method.
Responding to all currents bounding the zone of protection, the principle has a very high …
Responding to all currents bounding the zone of protection, the principle has a very high …
High speed digital distance relaying scheme using FPGA and IEC 61850
X **, R Gokaraju, R Wierckx… - IEEE Transactions on …, 2017 - ieeexplore.ieee.org
Full-cycle Fourier and cosine phasor filtering systems are typical implementations of
numerical distance relays with a response time of close to one cycle. Fast subcycle …
numerical distance relays with a response time of close to one cycle. Fast subcycle …
Differential protection of microgrids with central protection unit support
Deployments of Distributed Generators (DGs) have large impacts on the structure of
electrical networks. In order to tackle these issues, theMicrogrid'concept has been proposed …
electrical networks. In order to tackle these issues, theMicrogrid'concept has been proposed …
[HTML][HTML] Analysis and design of overcurrent protection for grid-connected microgrid with PV generation
This paper aimed to demonstrate the reliability of the Over Current protection (OCP) scheme
in protecting microgrids with inverter interfaced RES for low voltage distribution networks. To …
in protecting microgrids with inverter interfaced RES for low voltage distribution networks. To …
Current differential protection of transmission line using the moving window averaging technique
We propose a new approach to current differential protection of transmission lines. In this
approach, we transform the instantaneous line current (s) by using a moving window …
approach, we transform the instantaneous line current (s) by using a moving window …
Design and development of a communication-assisted microgrid protection system
TS Ustun - 2013 - vuir.vu.edu.au
Climate change concerns due to the rising amounts of the carbon gas in the atmosphere
have in the last decade or so initiated a fast pace of technological advances in the …
have in the last decade or so initiated a fast pace of technological advances in the …