Radiochromic film for medical radiation dosimetry
Photon, electron and proton radiations are used extensively for medical purposes in
diagnostic and therapeutic procedures. Dosimetry of these radiation sources can be …
diagnostic and therapeutic procedures. Dosimetry of these radiation sources can be …
Advances in kilovoltage x-ray beam dosimetry
This topical review provides an up-to-date overview of the theoretical and practical aspects
of therapeutic kilovoltage x-ray beam dosimetry. Kilovoltage x-ray beams have the property …
of therapeutic kilovoltage x-ray beam dosimetry. Kilovoltage x-ray beams have the property …
AAPM TG 158: measurement and calculation of doses outside the treated volume from external‐beam radiation therapy
The introduction of advanced techniques and technology in radiotherapy has greatly
improved our ability to deliver highly conformal tumor doses while minimizing the dose to …
improved our ability to deliver highly conformal tumor doses while minimizing the dose to …
Image guidance doses delivered during radiotherapy: Quantification, management, and reduction: Report of the AAPM Therapy Physics Committee Task Group 180
Background With radiotherapy having entered the era of image guidance, or image‐guided
radiation therapy (IGRT), imaging procedures are routinely performed for patient positioning …
radiation therapy (IGRT), imaging procedures are routinely performed for patient positioning …
A review of recent advances in optical fibre sensors for in vivo dosimetry during radiotherapy
This article presents an overview of the recent developments and requirements in
radiotherapy dosimetry, with particular emphasis on the development of optical fibre …
radiotherapy dosimetry, with particular emphasis on the development of optical fibre …
[HTML][HTML] Medical physics aspects of the synchrotron radiation therapies: Microbeam radiation therapy (MRT) and synchrotron stereotactic radiotherapy (SSRT)
Abstract Stereotactic Synchrotron Radiotherapy (SSRT) and Microbeam Radiation Therapy
(MRT) are both novel approaches to treat brain tumor and potentially other tumors using …
(MRT) are both novel approaches to treat brain tumor and potentially other tumors using …
Energy dependence of response of new high sensitivity radiochromic films for megavoltage and kilovoltage radiation energies
ST Chiu‐Tsao, Y Ho, R Shankar, L Wang… - Medical …, 2005 - Wiley Online Library
The purpose of this paper is to evaluate the energy dependence of the response of two new
high sensitivity models of radiochromic films EBT and XR‐QA. We determined the dose …
high sensitivity models of radiochromic films EBT and XR‐QA. We determined the dose …
Electronic dosimetry in radiation therapy
AB Rosenfeld - Radiation measurements, 2006 - Elsevier
Radiation therapy became more and more sophisticated in terms of radiation oncology
modalities, type of radiation used and method of delivery that is leading to very conformal …
modalities, type of radiation used and method of delivery that is leading to very conformal …
Study of out‐of‐field dose in photon radiotherapy: A commercial treatment planning system versus measurements and Monte Carlo simulations
B Sánchez‐Nieto, KN Medina‐Ascanio… - Medical …, 2020 - Wiley Online Library
Purpose An accurate assessment of out‐of‐field dose is necessary to estimate the risk of
second cancer after radiotherapy and the damage to the organs at risk surrounding the …
second cancer after radiotherapy and the damage to the organs at risk surrounding the …
Quantitative characterization of the X-ray beam at the Australian Synchrotron Imaging and Medical Beamline (IMBL)
A critical early phase for any synchrotron beamline involves detailed testing,
characterization and commissioning; this is especially true of a beamline as ambitious and …
characterization and commissioning; this is especially true of a beamline as ambitious and …