US building energy efficiency and flexibility as an electric grid resource

J Langevin, CB Harris, A Satre-Meloy… - Joule, 2021 - cell.com
Buildings use 75% of US electricity; therefore, improving the efficiency and flexibility of
building operations could provide significant value to the rapidly changing electricity system …

Integrating the sustainable development goals in building projects

S Goubran, C Cucuzzella - Journal of …, 2019 - spectrum.library.concordia.ca
Building designers are struggling to deeply integrate the 2030 Agenda and its Sustainable
Development Goals (SDGs) in projects. The review of the literature revealed that the …

Parametric study of double-skin facades performance in mild climate countries

A Alberto, NMM Ramos, RMSF Almeida - Journal of Building Engineering, 2017 - Elsevier
The application of double-skin facades is an interesting technical solution but, at the same
time, highly affected by the climatic conditions of the building location. Southern European …

Energy saving potential through Energy Conservation Building Code and advance energy efficiency measures in hotel buildings of Jaipur City, India

R Chedwal, J Mathur, GD Agarwal, S Dhaka - Energy and Buildings, 2015 - Elsevier
Commercial buildings of conventional practices consume significant energy, especially hotel
buildings. Therefore, the study aims to estimate energy saving potential in three categories …

Comparing methods of modeling air infiltration through building entrances and their impact on building energy simulations

S Goubran, D Qi, WF Saleh, LL Wang - Energy and Buildings, 2017 - Elsevier
Building entrance doors are a major source of air infiltration and energy loss in commercial
buildings. Previous studies have calculated entrance doors air infiltration and energy saving …

[PDF][PDF] Energy saving impact of ASHRAE 90.1 vestibule requirements: Modeling of air infiltration through door openings

H Cho, B Liu, K Gowri - 2010 - osti.gov
This report presents a methodology for modeling air infiltration through door openings. This
report shows that the estimation of air infiltration rate using the proposed method can be …

[PDF][PDF] Evaluation of Energy Efficiency and Thermal Comfort Delivery for a Novel Wall-Integrated Micro Heat Pump in Heating Mode

F Wu, S Alkandar, J Ma, P Dhillon, H Liu… - ASHRAE …, 2023 - researchgate.net
In this paper, we present a novel radiant heating system with a wall-integrated micro heat
pump that consists of a variable-speed miniature compressor, aluminum roll-bond …

[PDF][PDF] Technical support document: 50% energy savings for quick-service restaurants

J Zhang, DW Schrock, DR Fisher, A Livchak… - 2010 - osti.gov
Technical Support Document: 50% Energy Savings for Quick-Service Restaurants Page 1
PNNL-19809 Prepared for the US Department of Energy under Contract DE-AC05-76RL01830 …

Airflow and Energy Simulations to Assess Energy Savings from Vestibules and Air Curtains.

S Goubran, LL Wang, D Qi - ASHRAE Transactions, 2018 - search.ebscohost.com
Abstract ANSI/ASHRAE/IES Standard 90.1 requires vestibules to be installed in buildings in
climate zones 3 through 8 based on building energy simulations with a series of …

[PDF][PDF] Getting to zero: A pathway to a carbon neutral Seattle

M Lazarus, P Erickson, C Chandler, M Daudon… - … Institute (SEI)-US …, 2011 - lpdd.org
Cities play a unique role in addressing climate change. Over 80% of Americans live in urban
areas, as does over half of the world's population. As a consequence, the design of cities …