Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
Long-axial field-of-view PET/CT: perspectives and review of a revolutionary development in nuclear medicine based on clinical experience in over 7000 patients
Recently introduced long-axial field-of-view (LAFOV) PET/CT systems represent one of the
most significant advancements in nuclear medicine since the advent of multi-modality …
most significant advancements in nuclear medicine since the advent of multi-modality …
Theranostic approaches in nuclear medicine: current status and future prospects
L Filippi, A Chiaravalloti, O Schillaci… - Expert review of …, 2020 - Taylor & Francis
Introduction: Theranostics is an emerging field in which diagnosis and specific targeted
therapy are combined to achieve a personalized treatment approach to the patient. In …
therapy are combined to achieve a personalized treatment approach to the patient. In …
Performance characteristics of the Biograph Vision Quadra PET/CT system with a long axial field of view using the NEMA NU 2-2018 standard
GA Prenosil, H Sari, M Fürstner… - Journal of nuclear …, 2022 - jnm.snmjournals.org
Our purpose was to evaluate the performance of the Biograph Vision Quadra PET/CT
system. This new system is based on the Biograph Vision 600, using the same silicon …
system. This new system is based on the Biograph Vision 600, using the same silicon …
Clinical performance of long axial field of view PET/CT: a head-to-head intra-individual comparison of the Biograph Vision Quadra with the Biograph Vision PET/CT
Purpose To investigate the performance of the new long axial field-of-view (LAFOV)
Biograph Vision Quadra PET/CT and a standard axial field-of-view (SAFOV) Biograph Vision …
Biograph Vision Quadra PET/CT and a standard axial field-of-view (SAFOV) Biograph Vision …
Focal unspecific bone uptake on [18F]-PSMA-1007 PET: a multicenter retrospective evaluation of the distribution, frequency, and quantitative parameters of a …
H Grünig, A Maurer, Y Thali, Z Kovacs, K Strobel… - European Journal of …, 2021 - Springer
Purpose Improved logistics and availability led to a rapid increase in the use of [18 F]-PSMA-
1007 for prostate cancer PET imaging. Initial data suggests increased uptake in benign …
1007 for prostate cancer PET imaging. Initial data suggests increased uptake in benign …
A cross-scanner and cross-tracer deep learning method for the recovery of standard-dose imaging quality from low-dose PET
S Xue, R Guo, KP Bohn, J Matzke, M Viscione… - European journal of …, 2022 - Springer
Purpose A critical bottleneck for the credibility of artificial intelligence (AI) is replicating the
results in the diversity of clinical practice. We aimed to develop an AI that can be …
results in the diversity of clinical practice. We aimed to develop an AI that can be …
Long axial field-of-view PET/CT devices: are we ready for the technological revolution?
L Filippi, A Dimitrakopoulou-Strauss… - Expert Review of …, 2022 - Taylor & Francis
In last decades hybrid imaging, combining molecular and anatomical data in a unique,
synergistic approach, has thoroughly changed the face of medical diagnostics [1, 2]. In …
synergistic approach, has thoroughly changed the face of medical diagnostics [1, 2]. In …
Intraindividual comparison of [68 Ga]-Ga-PSMA-11 and [18F]-F-PSMA-1007 in prostate cancer patients: a retrospective single-center analysis
Background The analysis aimed to compare the radiotracers [68 Ga]-Ga-PSMA-11 and [18
F]-F-PSMA-1007 intraindividually in terms of malignant lesions, mi (molecular-imaging) TNM …
F]-F-PSMA-1007 intraindividually in terms of malignant lesions, mi (molecular-imaging) TNM …
Digital PET vs analog PET: clinical implications?
DA López-Mora, I Carrió, A Flotats - Seminars in Nuclear Medicine, 2022 - Elsevier
Positron emission tomography (PET) is a functional imaging technique introduced in 1970s.
Over the years, PET was used alone but is in 2000 when the first hybrid PET/CT device was …
Over the years, PET was used alone but is in 2000 when the first hybrid PET/CT device was …
Assessment of malignancy and PSMA expression of uncertain bone foci in [18F]PSMA-1007 PET/CT for prostate cancer—a single-centre experience of PET-guided …
B Vollnberg, I Alberts, V Genitsch, A Rominger… - European journal of …, 2022 - Springer
Purpose Uncertain focal bone uptake (UBU) with intensive radiopharmaceutical avidity are
frequently observed in patients undergoing [18F] PSMA-1007 PET/CT for the detection of …
frequently observed in patients undergoing [18F] PSMA-1007 PET/CT for the detection of …