MR imaging of hip arthroplasty implants
Hip arthroplasty has become the standard treatment for end-stage hip disease, allowing
pain relief and restoration of mobility in large numbers of patients; however, pain after hip …
pain relief and restoration of mobility in large numbers of patients; however, pain after hip …
Osteoporosis and orthopedic surgery: effect of bone health on total joint arthroplasty outcome
LA Russell - Current rheumatology reports, 2013 - Springer
Osteoporosis is a common condition. As the population ages, more patients with
osteoporosis will require orthopedic procedures, including arthroplasty. Adverse outcomes …
osteoporosis will require orthopedic procedures, including arthroplasty. Adverse outcomes …
Hyaluronic acid–British anti-Lewisite as a safer chelation therapy for the treatment of arthroplasty-related metallosis
Cobalt-containing alloys are useful for orthopedic applications due to their low volumetric
wear rates, corrosion resistance, high mechanical strength, hardness, and fatigue …
wear rates, corrosion resistance, high mechanical strength, hardness, and fatigue …
Metal artifact reduction with MAVRIC SL at 3-T MRI in patients with hip arthroplasty
OBJECTIVE. The objective of our study was to compare the multiacquisition variable-
resonance image combination selective (MAVRIC SL) sequence with the 2D fast spin-echo …
resonance image combination selective (MAVRIC SL) sequence with the 2D fast spin-echo …
Advanced metal artifact reduction MRI of metal-on-metal hip resurfacing arthroplasty implants: compressed sensing acceleration enables the time-neutral use of …
Objective Compressed sensing (CS) acceleration has been theorized for slice encoding for
metal artifact correction (SEMAC), but has not been shown to be feasible. Therefore, we …
metal artifact correction (SEMAC), but has not been shown to be feasible. Therefore, we …
Visual and quantitative assessment of hip implant-related metal artifacts at low field MRI: a phantom study comparing a 0.55-T system with 1.5-T and 3-T systems
HC Breit, J Vosshenrich, M Clauss, TJ Weikert… - European Radiology …, 2023 - Springer
Background To investigate hip implant-related metal artifacts on a 0.55-T system compared
with 1.5-T and 3-T systems. Methods Total hip arthroplasty made of three different alloys …
with 1.5-T and 3-T systems. Methods Total hip arthroplasty made of three different alloys …
High frequency of adverse local tissue reactions in asymptomatic patients with metal-on-metal THA
TK Fehring, S Odum, R Sproul… - Clinical Orthopaedics and …, 2014 - Springer
Background The key to successful management of patients with metal-on-metal (MOM)
THAs is to diagnose adverse local tissue reactions (ALTRs) early. ALTRs have been …
THAs is to diagnose adverse local tissue reactions (ALTRs) early. ALTRs have been …
Metal-on-metal total hip arthroplasty: patient evaluation and treatment
MP Bolognesi, CK Ledford - … -Journal of the American Academy of …, 2015 - journals.lww.com
Abstract Metal-on-metal (MoM) hip articulations were thought to represent a biologic and
biomechanically favorable alternative to conventional metal-on-polyethylene total hip …
biomechanically favorable alternative to conventional metal-on-polyethylene total hip …
Implant based differences in adverse local tissue reaction in failed total hip arthroplasties: a morphological and immunohistochemical study
Background Adverse local tissue reaction (ALTR) is characterized by periprosthetic soft
tissue inflammation composed of a mixed inflammatory cell infiltrate, extensive soft tissue …
tissue inflammation composed of a mixed inflammatory cell infiltrate, extensive soft tissue …
Comprehensive analysis of a recalled modular total hip system and recommendations for management
DH Nawabi, HT Do, A Ruel, B Lurie, ME Elpers… - JBJS, 2016 - journals.lww.com
Background: Recent total hip arthroplasty designs have introduced modularity at the neck-
stem junction. There are reports of failure of this class of designs due to corrosion at the …
stem junction. There are reports of failure of this class of designs due to corrosion at the …