Recent and upcoming technological developments in computed tomography: high speed, low dose, deep learning, multienergy

MM Lell, M Kachelrieß - Investigative radiology, 2020 - journals.lww.com
The advent of computed tomography (CT) has revolutionized radiology, and this revolution
is still going on. Starting as a pure head scanner, modern CT systems are now able to …

Current and novel techniques for metal artifact reduction at CT: practical guide for radiologists

M Katsura, J Sato, M Akahane, A Kunimatsu, O Abe - Radiographics, 2018 - pubs.rsna.org
Artifacts caused by metallic implants appear as dark and bright streaks at computed
tomography (CT), which severely degrade the image quality and decrease the diagnostic …

Convolutional neural network based metal artifact reduction in X-ray computed tomography

Y Zhang, H Yu - IEEE transactions on medical imaging, 2018 - ieeexplore.ieee.org
In the presence of metal implants, metal artifacts are introduced to x-ray computed
tomography CT images. Although a large number of metal artifact reduction (MAR) methods …

Dudonet: Dual domain network for ct metal artifact reduction

WA Lin, H Liao, C Peng, X Sun… - Proceedings of the …, 2019 - openaccess.thecvf.com
Computed tomography (CT) is an imaging modality widely used for medical diagnosis and
treatment. CT images are often corrupted by undesirable artifacts when metallic implants are …

ADN: artifact disentanglement network for unsupervised metal artifact reduction

H Liao, WA Lin, SK Zhou, J Luo - IEEE Transactions on Medical …, 2019 - ieeexplore.ieee.org
Current deep neural network based approaches to computed tomography (CT) metal artifact
reduction (MAR) are supervised methods that rely on synthesized metal artifacts for training …

Metal artifact reduction in CT: where are we after four decades?

L Gjesteby, B De Man, Y **, H Paganetti… - Ieee …, 2016 - ieeexplore.ieee.org
Methods to overcome metal artifacts in computed tomography (CT) images have been
researched and developed for nearly 40 years. When X-rays pass through a metal object …

Photon counting CT: clinical applications and future developments

SS Hsieh, S Leng, K Rajendran, S Tao… - IEEE transactions on …, 2020 - ieeexplore.ieee.org
The use of a photon counting detector in CT (PCD CT) is currently the subject of intense
investigation and development. In this review article, we will describe potential clinical …

[HTML][HTML] A review of the methods on cobb angle measurements for spinal curvature

C **, S Wang, G Yang, E Li, Z Liang - Sensors, 2022 - mdpi.com
Scoliosis is a common disease of the spine and requires regular monitoring due to its
progressive properties. A preferred indicator to assess scoliosis is by the Cobb angle, which …

Advances in metal artifact reduction in CT images: A review of traditional and novel metal artifact reduction techniques

M Selles, JAC van Osch, M Maas, MF Boomsma… - European Journal of …, 2024 - Elsevier
Metal artifacts degrade CT image quality, hampering clinical assessment. Numerous metal
artifact reduction methods are available to improve the image quality of CT images with …

Deep sinogram completion with image prior for metal artifact reduction in CT images

L Yu, Z Zhang, X Li, L **ng - IEEE transactions on medical …, 2020 - ieeexplore.ieee.org
Computed tomography (CT) has been widely used for medical diagnosis, assessment, and
therapy planning and guidance. In reality, CT images may be affected adversely in the …