Reference Power Supply Connection Scheme for Low-Power CMOS Image Sensors Based on Incremental Sigma-Delta Converters
LM Carvalho Freitas, F Morgado-Dias - Electronics, 2021 - mdpi.com
Modern Complementary Metal-Oxide-Semiconductor (CMOS) image sensors, aimed to
target low-noise and fast digital outputs, are fundamentally based on column-parallel …
target low-noise and fast digital outputs, are fundamentally based on column-parallel …
Ultra-low-power analog-to-digital converters for medical applications
D Zhang - 2014 - diva-portal.org
Biomedical systems are commonly attached to or implanted into human bodies, and
powered by harvested energy or small batteries. In these systems, analog-to-digital …
powered by harvested energy or small batteries. In these systems, analog-to-digital …
9.9 µW, 140 dB DR, and 93.27 dB SNDR, Double Sampling ΔΣ Modulator Using High Swing Inverter-Based Amplifier for Digital Hearing Aids
In this paper, an ultra-low-power second-order, single-bit discrete-time (DT) double
sampling ΔΣ modulator was proposed for hearing aid applications. In portable biomedical …
sampling ΔΣ modulator was proposed for hearing aid applications. In portable biomedical …
A 300-mV ΔΣ Modulator Using a Gain-Enhanced, Inverter-Based Amplifier for Medical Implant Devices
A Fazli Yeknami - Journal of Low Power Electronics and Applications, 2016 - mdpi.com
An ultra-low-voltage low-power switched-capacitor (SC) delta-sigma (ΔΣ) modulator running
at a supply voltage as low as 300 mV is presented for biomedical implant devices, eg …
at a supply voltage as low as 300 mV is presented for biomedical implant devices, eg …
Accurate Data Acquisition Circuit for MEMS Accelerometer
SG Basha, J Tibrewal, PS Rao - 2022 IEEE International …, 2022 - ieeexplore.ieee.org
Microsensor systems that can monitor diverse physical variables, such as location,
accelerometer, angular velocity, and fluid properties to determine the external environment …
accelerometer, angular velocity, and fluid properties to determine the external environment …
Design and simulation of fourth order sigma-delta modulator using parametric amplifier with dynamic threshold for digital hearing aid application
S Alizadeh Zanjani, A Jannesari… - Journal of Southern …, 2023 - jce.bushehr.iau.ir
In this paper, a fourth-order, OTA-free, single-bit, low-consumption discrete-time (DT) delta-
sigma (ΔΣ) modulator with CIFF structure is proposed for hearing aid applications. In …
sigma (ΔΣ) modulator with CIFF structure is proposed for hearing aid applications. In …
[PDF][PDF] Design and Simulation of Ultra-Low-Power Sigma-Delta Converter Using the Fully Differential Inverter-Based Amplifier for Digital Hearing Aids Application
PD Shima Alizadeh Zanjani, A Jannesari, P Torkzadeh - jipet.iaun.iau.ir
In this paper, an ultra-low-power, second-order, discrete-time sigma-delta converter is
proposed for hearing aids application. In portable biomedical devices such as hearing aids …
proposed for hearing aids application. In portable biomedical devices such as hearing aids …
Reference Power Supply Connection Scheme for Low-Power CMOS Image Sensors Based on Incremental Sigma-Delta Converters. Electronics 2021, 10, 299
LM Carvalho Freitas, F Morgado-Dias - 2021 - search.proquest.com
Abstract Modern Complementary Metal-Oxide-Semiconductor (CMOS) image sensors,
aimed to target low-noise and fast digital outputs, are fundamentally based on column …
aimed to target low-noise and fast digital outputs, are fundamentally based on column …
طراحی و شبیه سازی مبدل سیگما دلتای فوق کم مصرف با استفاده از تقویت کننده تمام تفاضلی مبتنی بر اینورتر برای کاربرد سمعک دیجیتال
علی زاده زنجانی شیما, جان نثاری ابومسلم, ترکزاده پویا - 2022 - sid.ir
این مقاله, یک مبدل سیگما دلتای زمان گسسته فوق کم مصرف مرتبه دوم, برای کاربرد سمعک
پیشنهاد شده است. در تجهیزات پزشکی مانند سمعک که دایما استفاده می شود, طول عمر باتری و …
پیشنهاد شده است. در تجهیزات پزشکی مانند سمعک که دایما استفاده می شود, طول عمر باتری و …
Correlated double sampling integrating circuit
M Zhang, C Zhan - US Patent 10,395,746, 2019 - Google Patents
A correlated double sampling integrating circuit is provided. The circuit includes: a sampling
and holding module, an energy storage unit and a feedback module. The sampling and …
and holding module, an energy storage unit and a feedback module. The sampling and …