[HTML][HTML] Model-free inertia estimation in bulk power grids through O-splines
This paper proposes a novel methodology to precisely estimate the generation units' inertia
constant by using the wide-area monitoring systems (WAMS) information of bulk power …
constant by using the wide-area monitoring systems (WAMS) information of bulk power …
Assessing synchrophasor estimates of an event captured by a phasor measurement unit
Synchrophasor estimators are nowadays evaluated with the Total Vector Error (TVE) using
the synchrophasor representations of the few benchmark signals. This synchrophasor …
the synchrophasor representations of the few benchmark signals. This synchrophasor …
An Optimization of Least-Square Harmonic Phasor Estimators in Presence of Multi-Interference and Harmonic Frequency Variance
The wide application of power electronic devices brings an increasing amount of undesired
harmonic and interharmonic tones, and accurate harmonic phasor estimation under a …
harmonic and interharmonic tones, and accurate harmonic phasor estimation under a …
O splines-based fixed-frequency integral sliding-mode controller for PFC rectifier
This article proposes a fast-response sliding mode controller for a semibridgeless boost
converter under large and quick load fluctuations to ensure tight output voltage regulation …
converter under large and quick load fluctuations to ensure tight output voltage regulation …
An embedded estimator for online harmonic monitoring in power-electronic grids
A real-time harmonic estimator is proposed to provide a high-accuracy, computationally-
efficient, and low-cache-cost solution that can be applied in embedded system for the online …
efficient, and low-cache-cost solution that can be applied in embedded system for the online …
A morlet wavelet-based two-point FIR filter method for phasor estimation
This article proposes a method of phasor estimation called the Morlet wavelet-based two-
point finite-impulse response (FIR) filter (MW-FIR), showing advantages on algorithm …
point finite-impulse response (FIR) filter (MW-FIR), showing advantages on algorithm …
P class and M class compliant PMU based on discrete-time frequency-gain transducer
Phasor Measurement Units (PMUs) are widely used in the Smart Grids (SGs). In this paper
we propose the discrete-time frequency-gain transducer (DTFGT) and we apply it for PMU …
we propose the discrete-time frequency-gain transducer (DTFGT) and we apply it for PMU …
Estimation of Wideband Multi-Component Phasors Considering Signal Dam**
Harmonic and interharmonic content in power system signals is increasing with the
development of renewable energy generation and power electronic devices. These multiple …
development of renewable energy generation and power electronic devices. These multiple …
Enhanced morlet wavelet-based two-point FIR for phasor estimation
X Liu, NKC Nair - IEEE Transactions on Smart Grid, 2022 - ieeexplore.ieee.org
Recently, a new approach called Morlet wavelet-based two-point FIR (MW-FIR) is proposed
for the phasor estimation. Although the approach shows several advantages, it is still not …
for the phasor estimation. Although the approach shows several advantages, it is still not …
Taylor–Fourier filter-bank implemented with O-splines for the detection and classification of faults
The article proposes a new method based on a Taylor-Fourier filter-bank implemented with
O-splines for the detection and classification of faults. This method defines a multiresolution …
O-splines for the detection and classification of faults. This method defines a multiresolution …