Measurement of mean thickness of transparent samples using simultaneous phase shifting interferometry with four interferograms

VH Flores Muñoz, NIT Arellano, DI Serrano García… - Applied Optics, 2016 - opg.optica.org
In this research a novel interferometric system is reported, which allows the generation of
four simultaneous interferograms with phase shifts of π/2. The system consists of three …

Common path interferometer based on the modified Michelson configuration using a reflective grating

H Bai, M Shan, Z Zhong, L Guo, Y Zhang - Optics and Lasers in …, 2015 - Elsevier
A common-path interferometer using the modified Michelson system with a reflective grating
is proposed for quantitative phase imaging. The frequency spectrum of the object beam is …

4D measurements of biological and synthetic structures using a dynamic interferometer

NI Toto-Arellano - Journal of Modern optics, 2017 - Taylor & Francis
Considering the deficiency of time elapsed for phase-step** interferometric techniques
and the need of develo** non-contact and on-line measurement with high accuracy, a …

Parallel two-step phase shifting interferometry using a double cyclic shear interferometer

NI Toto-Arellano, DI Serrano-García… - Optics express, 2013 - opg.optica.org
A parallel two-step polarizing phase shifting interferometer based on a Double Cyclic Shear
Interferometer (DCSI) is proposed in this paper for quantitative phase imaging. The system …

Dynamic temperature field measurements using a polarization phase-shifting technique

DI Serrano-García, A Martínez-García… - Optical …, 2014 - spiedigitallibrary.org
In this study, an optical system capable of simultaneously grabbing three phase-shifted
interferometric images was developed for dynamic temperature field measurements of a thin …

Parallel-quadrature on-axis phase-shifting common-path interferometer using a polarizing beam splitter

H Bai, M Shan, Z Zhong, L Guo, Y Zhang - Applied Optics, 2015 - opg.optica.org
A common-path parallel-quadrature on-axis phase-shifting interferometry using a modified
Michelson configuration with a polarizing cube beam splitter is proposed for quantitative …

Nonlinear refractive index measuring using a double-grating interferometer in pump–probe configuration and Fourier transform analysis

S Rasouli, M Ghorbani - Journal of Optics, 2012 - iopscience.iop.org
In this paper, we have presented a simple, stable, highly sensitive and timesaving method
based on a double-grating interferometer in conjunction with a pump–probe technique for …

Measurement of red blood cell characteristic using parallel phase shifting interferometry

VHF Muñoz, NI Toto-Arellano, B López-Ortiz… - Optik, 2015 - Elsevier
In this research, an interferometric technique is presented for the calculation of the optical
path difference (OPD) induced by a red blood cell (RBC) to measure its 3D phase profile …

Radial slope measurement of dynamic transparent samples

DI Serrano-García, NI Toto-Arellano… - Journal of …, 2012 - iopscience.iop.org
An interferometric method to measure the radial slope of dynamic transparent samples is
presented. We have implemented a simultaneous phase shifting Mach–Zehnder radial …

Dynamic phase imaging of microscopic measurements using parallel interferograms generated from a cyclic shear interferometer

NI Toto-Arellano, VH Flores-Muñoz, B Lopez-Ortiz - Optics express, 2014 - opg.optica.org
We present a technique which allows us to generate two parallel interferograms with phase
shifts of π/2 using a Cyclic Shear Interferometer (CSI) and a polarizing splitter. Because of …