Cuffless blood pressure measurement

R Mukkamala, GS Stergiou… - Annual Review of …, 2022 - annualreviews.org
Cuffless blood pressure (BP) measurement has become a popular field due to clinical need
and technological opportunity. However, no method has been broadly accepted hitherto …

Noninvasive continuous blood pressure estimation from pulse transit time: A review of the calibration models

D Barvik, M Cerny, M Penhaker… - IEEE reviews in …, 2021 - ieeexplore.ieee.org
Noninvasive continuous blood pressure estimation is a promising alternative to minimally
invasive blood pressure measurement using cuff and invasive catheter measurement …

Pulse arrival time as a surrogate of blood pressure

E Finnegan, S Davidson, M Harford, J Jorge… - Scientific reports, 2021 - nature.com
Various models have been proposed for the estimation of blood pressure (BP) from pulse
transit time (PTT). PTT is defined as the time delay of the pressure wave, produced by left …

Unconstrained blood pressure monitoring based on a neural network–assisted multistage pressure textile sensor

S Si, C Sun, H Wang, H Wu, L Chen, Y **a, J Qin, Y Wu… - Nano Energy, 2023 - Elsevier
Non-invasive blood pressure (NIBP) assessment via constrained wearable devices aided by
intelligent algorithms has led to tremendous advancements in healthcare. However, existing …

Conventional pulse transit times as markers of blood pressure changes in humans

RC Block, M Yavarimanesh, K Natarajan, A Carek… - Scientific Reports, 2020 - nature.com
Pulse transit time (PTT) represents a potential approach for cuff-less blood pressure (BP)
monitoring. Conventionally, PTT is determined by (1) measuring (a) ECG and ear, finger, or …

Efficient detection of aortic stenosis using morphological characteristics of cardiomechanical signals and heart rate variability parameters

A Shokouhmand, ND Aranoff, E Driggin, P Green… - Scientific reports, 2021 - nature.com
Recent research has shown promising results for the detection of aortic stenosis (AS) using
cardio-mechanical signals. However, they are limited by two main factors: lacking physical …

A new method of continuous blood pressure monitoring using multichannel sensing signals on the wrist

L Wang, S Tian, R Zhu - Microsystems & Nanoengineering, 2023 - nature.com
Hypertension is a worldwide health problem and a primary risk factor for cardiovascular
disease. Continuous monitoring of blood pressure has important clinical value for the early …

Advancement in the cuffless and noninvasive measurement of blood pressure: A review of the literature and open challenges

MMR Khan Mamun, A Sherif - Bioengineering, 2022 - mdpi.com
Hypertension is a chronic condition that is one of the prominent reasons behind
cardiovascular disease, brain stroke, and organ failure. Left unnoticed and untreated, the …

A comparison of wearable tonometry, photoplethysmography, and electrocardiography for cuffless measurement of blood pressure in an ambulatory setting

R Mieloszyk, H Twede, J Lester… - IEEE Journal of …, 2022 - ieeexplore.ieee.org
Objective: While non-invasive, cuffless blood pressure (BP) measurement has demonstrated
relevancy in controlled environments, ambulatory measurement is important for …

Continuous non-invasive blood pressure monitoring: a methodological review on measurement techniques

T Le, F Ellington, TY Lee, K Vo, M Khine… - IEEE …, 2020 - ieeexplore.ieee.org
Continuous measurement of blood pressure is crucial to the assessment of many medical
conditions. However, the current clinical gold standard involving an arterial catheter …