Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
[HTML][HTML] Analytical solution of serial ferroresonance triggered by circuit breaker operation in solidly grounded power grids
Ferroresonance can be induced by Circuit Breaker (CB) switching operations in neutral
point solidly grounded power grids with matching parameters. No complete time domain …
point solidly grounded power grids with matching parameters. No complete time domain …
Analysis and simulation of ferroresonance in power transformers using simulink
RP Pineda, R Rodrigues… - IEEE Latin America …, 2018 - ieeexplore.ieee.org
This paper presents a study using Simulink to investigate the response of the voltage
transformers to the phenomenon of ferroresonance. In analyzing the behavior of this …
transformers to the phenomenon of ferroresonance. In analyzing the behavior of this …
Dual function ferroresonance and fault current limiter based on DC reactor
This study presents a novel DC reactor‐based ferroresonance and fault current limiter
(DRFFCL) for stabilising ferroresonance oscillations of potential transformer (PT) in 33 kV …
(DRFFCL) for stabilising ferroresonance oscillations of potential transformer (PT) in 33 kV …
Compound ferroresonance overvoltage and fault current limiter for power system protection
Power systems are subjected to various types of faults as well as ferroresonance
overvoltages. These results in the interruption of the normal operation of the power grid …
overvoltages. These results in the interruption of the normal operation of the power grid …
Distribution network protection using smart dual functional series resonance-based fault current and ferroresonance overvoltage limiter
This paper proposes a smart dual function series resonance ferroresonance overvoltage
and fault current limiter (SRFFCL) for distribution networks. The studied network has …
and fault current limiter (SRFFCL) for distribution networks. The studied network has …
Experimental registration and numerical simulation of the transient overvoltages caused by single phase intermittent arc earth fault in 35 kV network with isolated …
The paper presents the results of experimental registrations and numerical simulations of
the transient overvoltages caused by single phase intermittent arc earth fault in 35 kV …
the transient overvoltages caused by single phase intermittent arc earth fault in 35 kV …
Impact of the eddy current in the lamination on ferroresonance stability at critical points
The susceptibility of ferroresonance to the eddy current in the iron core is presented in this
paper. The stability of ferroresonance modes is investigated regarding to the eddy current in …
paper. The stability of ferroresonance modes is investigated regarding to the eddy current in …
Extraction of transformer saturation curve from ferroresonance measurements based on Nelder− Mead optimization method
An accurate representation of the transformer saturation curve is essential for calculations of
low frequency transients (inrush current, ferroresonance, load rejection) and steady states …
low frequency transients (inrush current, ferroresonance, load rejection) and steady states …
Determination of single-phase transformer saturation characteristic by using Nelder–Mead optimization method
Correctly modelling the nonlinear saturation characteristics of the transformer iron core is of
great importance in steady-state calculations (harmonics and power quality) and …
great importance in steady-state calculations (harmonics and power quality) and …
An efficient method for investigating the ferroresonance of single-phase iron core devices
The paper presents a fast and efficient method for determining the solutions of the
ferroresonant circuits generated at the switching of different single-phase low-voltage iron …
ferroresonant circuits generated at the switching of different single-phase low-voltage iron …