Comparison of two x-ray phase-contrast imaging methods with a microfocus source
We present a comparison for high-resolution imaging with a laboratory source between
grating-based (GBI) and propagation-based (PBI) x-ray phase-contrast imaging. The …
grating-based (GBI) and propagation-based (PBI) x-ray phase-contrast imaging. The …
Modeling and design of a cone-beam CT head scanner using task-based imaging performance optimization
Detection of acute intracranial hemorrhage (ICH) is important for diagnosis and treatment of
traumatic brain injury, stroke, postoperative bleeding, and other head and neck injuries. This …
traumatic brain injury, stroke, postoperative bleeding, and other head and neck injuries. This …
Grating‐based phase contrast tomosynthesis imaging: proof‐of‐concept experimental studies
Purpose: This paper concerns the feasibility of x‐ray differential phase contrast (DPC)
tomosynthesis imaging using a grating‐based DPC benchtop experimental system, which is …
tomosynthesis imaging using a grating‐based DPC benchtop experimental system, which is …
Task-driven optimization of the non-spectral mode of photon counting CT for intracranial hemorrhage assessment
Non-contrast CT (NCCT) is widely employed as the first-line imaging test to evaluate
intracranial hemorrhage (ICH). Advances in mutidetector CT (MDCT) technology have …
intracranial hemorrhage (ICH). Advances in mutidetector CT (MDCT) technology have …
Dual energy differential phase contrast CT (DE-DPC-CT) imaging
When more than two elemental materials are present in a given object, material
quantification may not be robust and accurate when the routine two-material decomposition …
quantification may not be robust and accurate when the routine two-material decomposition …
Impact of anti-charge sharing on the zero-frequency detective quantum efficiency of CdTe-based photon counting detector system: cascaded systems analysis and …
Inter-pixel communication and anti-charge sharing (ACS) technologies have been
introduced to photon counting detector (PCD) systems to address the undesirable charge …
introduced to photon counting detector (PCD) systems to address the undesirable charge …
Image quality models for 2D and 3D x‐ray imaging systems: a perspective vignette
JH Siewerdsen - Medical physics, 2023 - Wiley Online Library
Image quality models based on cascaded systems analysis and task‐based imaging
performance were an important aspect of the emergence of 2D and 3D digital x‐ray systems …
performance were an important aspect of the emergence of 2D and 3D digital x‐ray systems …
Correlation between human observer performance and model observer performance in differential phase contrast CT
Purpose: With the recently expanding interest and developments in x‐ray differential phase
contrast CT (DPC‐CT), the evaluation of its task‐specific detection performance and …
contrast CT (DPC‐CT), the evaluation of its task‐specific detection performance and …
Automatic CT simulation optimization for radiation therapy: a general strategy
Purpose: In radiation therapy, x‐ray computed tomography (CT) simulation protocol
specifications should be driven by the treatment planning requirements in lieu of duplicating …
specifications should be driven by the treatment planning requirements in lieu of duplicating …
Spatial resolution characterization of differential phase contrast CT systems via modulation transfer function (MTF) measurements
Abstract By adding a Talbot–Lau interferometer to a conventional x-ray absorption computed
tomography (CT) imaging system, both differential phase contrast (DPC) signal and …
tomography (CT) imaging system, both differential phase contrast (DPC) signal and …