Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
The delay multiply and sum beamforming algorithm in ultrasound B-mode medical imaging
Most of ultrasound medical imaging systems currently on the market implement standard
Delay and Sum (DAS) beamforming to form B-mode images. However, image resolution and …
Delay and Sum (DAS) beamforming to form B-mode images. However, image resolution and …
Benefits of minimum-variance beamforming in medical ultrasound imaging
Recently, significant improvement in image resolution has been demonstrated by applying
adaptive beamforming to medical ultrasound imaging. In this paper, we have used the …
adaptive beamforming to medical ultrasound imaging. In this paper, we have used the …
Minimum variance beamforming combined with adaptive coherence weighting applied to medical ultrasound imaging
Currently, the nonadaptive delay-and-sum (DAS) beamformer is used in medical ultrasound
imaging. However, due to its data-independent nature, DAS leads to images with limited …
imaging. However, due to its data-independent nature, DAS leads to images with limited …
Wiener beamforming and the coherence factor in ultrasound imaging
The coherence factor (CF) is used for aberration correction and sidelobe suppression in
ultrasound imaging. Unfortunately, it suffers from artifacts when the SNR is low. We show …
ultrasound imaging. Unfortunately, it suffers from artifacts when the SNR is low. We show …
Eigenspace-based minimum variance beamforming applied to medical ultrasound imaging
Recently, adaptive beamforming methods have been successfully applied to medical
ultrasound imaging, resulting in significant improvement in image quality compared with non …
ultrasound imaging, resulting in significant improvement in image quality compared with non …
[HTML][HTML] Achieving depth-independent lateral resolution in AR-PAM using the synthetic-aperture focusing technique
Acoustic-resolution photoacoustic microscopy (AR-PAM) is a promising imaging modality
that renders images with ultrasound resolution and extends the imaging depth beyond the …
that renders images with ultrasound resolution and extends the imaging depth beyond the …
Capon beamforming in medical ultrasound imaging with focused beams
F Vignon, MR Burcher - IEEE transactions on ultrasonics …, 2008 - ieeexplore.ieee.org
Medical ultrasound imaging is conventionally done by insonifying the imaged medium with
focused beams. The backscattered echoes are beamformed using delay-and-sum …
focused beams. The backscattered echoes are beamformed using delay-and-sum …
Beamspace adaptive beamforming for ultrasound imaging
CIC Nilsen, I Hafizovic - IEEE Transactions on Ultrasonics …, 2009 - ieeexplore.ieee.org
Applying the Capon adaptive beamformer in medical ultrasound imaging results in
enhanced resolution by improving the interference-suppressing capabilities of the array …
enhanced resolution by improving the interference-suppressing capabilities of the array …
A low-complexity adaptive beamformer for ultrasound imaging using structured covariance matrix
In recent years, adaptive beamforming methods have been successfully applied to medical
ultrasound imaging, resulting in simultaneous improvement in imaging resolution and …
ultrasound imaging, resulting in simultaneous improvement in imaging resolution and …
Contrast enhancement and robustness improvement of adaptive ultrasound imaging using forward-backward minimum variance beamforming
In adaptive ultrasound imaging, accurate estimation of the array covariance matrix is of great
importance, and biases the performance of the adaptive beamformer. The more accurately …
importance, and biases the performance of the adaptive beamformer. The more accurately …