Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
[HTML][HTML] A comparative study of alternative methods for 210Pb determination in environmental samples
E Cuesta, A Barba-Lobo, RL Lozano… - Radiation Physics and …, 2022 - Elsevier
The accurate determination of the levels of 210 Pb in environmental samples (eg
atmospheric aerosols, waters, soils, biota, etc.) is essential due to its multiple applications in …
atmospheric aerosols, waters, soils, biota, etc.) is essential due to its multiple applications in …
[HTML][HTML] Determination of radium and radon exhalation rate as a function of soil depth of Duhok Province-Iraq
WA Alhamdi, KMS Abdullah - Journal of Radiation Research and Applied …, 2021 - Elsevier
Radon is a naturally occurring radioactive gas; generated during the decay process of
radium, when alpha particles start to be emitted, turning the radium into radon. The rate of …
radium, when alpha particles start to be emitted, turning the radium into radon. The rate of …
Characterization and performance of co-axial HPGe detectors
High purity germanium (HPGe) detectors are deployed globally for gamma-radiation
spectroscopy due to their superior energy resolution. In this work, the essential …
spectroscopy due to their superior energy resolution. In this work, the essential …
Readout circuit for a ZnO bulk-acoustic-wave X-ray dose rate detector
Z Yu, J Bi, D Huang, X Zhao, Y He - Nuclear Instruments and Methods in …, 2024 - Elsevier
Abstract Bulk Acoustic Wave (BAW) resonators based on piezoelectric semiconductors are
radio frequency devices that can convert X-ray dose rate into resonant frequency offset …
radio frequency devices that can convert X-ray dose rate into resonant frequency offset …
Short-term exposures to particulate matter gamma radiation activities and biomarkers of systemic inflammation and endothelial activation in COPD patients
Background We hypothesized that particulate matter (PM) gamma activity (gamma radiation
associated with PM) is associated with systemic effects. Objective Examine short-term …
associated with PM) is associated with systemic effects. Objective Examine short-term …
Effects of particulate matter gamma radiation on oxidative stress biomarkers in COPD patients
Inhalation of particulate matter (PM) radioactivity is an important pathway of ionizing
radiation exposure. We investigated the associations between short-term exposures to PM …
radiation exposure. We investigated the associations between short-term exposures to PM …
[HTML][HTML] Analytical-numerical formula for estimating the characteristics of a cylindrical NaI (Tl) gamma-ray detector with a side-through hole
AA Thabet, MS Badawi - Nuclear Engineering and Technology, 2022 - Elsevier
NaI (Tl) scintillation materials are considered to be one of many materials that are used
exclusively for γ-ray detection and spectroscopy. The gamma-ray spectrometer is not an …
exclusively for γ-ray detection and spectroscopy. The gamma-ray spectrometer is not an …
Shielding design for high-intensity Co-60 and Ir-192 gamma sources used in industrial radiography based on PHITS Monte Carlo simulations
CJ Guembou Shouop, B Sang-In - The European Physical Journal Plus, 2020 - Springer
Protection in industrial radiography facilities has been a worldwide concern for decades and
the most appropriate protection for the public and operators in small scale facilities is the …
the most appropriate protection for the public and operators in small scale facilities is the …
Short-term exposure to ambient particle gamma radioactivity is associated with increased risk for all-cause non-accidental and cardiovascular mortality
Background Recent studies have found that particulate matter (PM) attached radioactivity
was associated with certain adverse health effects including increased blood pressure and …
was associated with certain adverse health effects including increased blood pressure and …
Optimization of the HPGe detector passive shields by Monte-Carlo simulations
The selection of appropriate materials and their thicknesses, which should be used for
germanium spectrometer shielding, is an important and complex task with the aim to reduce …
germanium spectrometer shielding, is an important and complex task with the aim to reduce …