Report of the AAPM Task Group No. 105: Issues associated with clinical implementation of Monte Carlo‐based photon and electron external beam treatment planning

IJ Chetty, B Curran, JE Cygler, JJ DeMarco… - Medical …, 2007 - Wiley Online Library
The Monte Carlo (MC) method has been shown through many research studies to calculate
accurate dose distributions for clinical radiotherapy, particularly in heterogeneous patient …

Monte Carlo simulations in radiotherapy dosimetry

P Andreo - Radiation Oncology, 2018 - Springer
Background The use of the Monte Carlo (MC) method in radiotherapy dosimetry has
increased almost exponentially in the last decades. Its widespread use in the field has …

Report of the Task Group 186 on model‐based dose calculation methods in brachytherapy beyond the TG‐43 formalism: current status and recommendations for …

L Beaulieu, Å Carlsson Tedgren, JF Carrier… - Medical …, 2012 - Wiley Online Library
The charge of Task Group 186 (TG‐186) is to provide guidance for early adopters of model‐
based dose calculation algorithms (MBDCAs) for brachytherapy (BT) dose calculations to …

[KNIHA][B] Handbook of radiotherapy physics: theory and practice

P Mayles, A Nahum, JC Rosenwald - 2007 - taylorfrancis.com
From background physics and biological models to the latest imaging and treatment
modalities, the Handbook of Radiotherapy Physics: Theory and Practice covers all …

Small animal radiotherapy research platforms

F Verhaegen, P Granton… - Physics in Medicine & …, 2011 - iopscience.iop.org
Advances in conformal radiation therapy and advancements in pre-clinical radiotherapy
research have recently stimulated the development of precise micro-irradiators for small …

Dosimetric validation of Acuros® XB with Monte Carlo methods for photon dose calculations

K Bush, IM Gagne, S Zavgorodni, W Ansbacher… - Medical …, 2011 - Wiley Online Library
Purpose: The dosimetric accuracy of the recently released Acuros® XB advanced dose
calculation algorithm (Varian Medical Systems, Palo Alto, CA) is investigated for single …

Comparison of dose calculation algorithms for treatment planning in external photon beam therapy for clinical situations

T Knöös, E Wieslander, L Cozzi, C Brink… - Physics in Medicine …, 2006 - iopscience.iop.org
A study of the performance of five commercial radiotherapy treatment planning systems
(TPSs) for common treatment sites regarding their ability to model heterogeneities and …

Dosimetric comparison of Acuros XB deterministic radiation transport method with Monte Carlo and model‐based convolution methods in heterogeneous media

T Han, JK Mikell, M Salehpour, F Mourtada - Medical Physics, 2011 - Wiley Online Library
Purpose: The deterministic Acuros XB (AXB) algorithm was recently implemented in the
Eclipse treatment planning system. The goal of this study was to compare AXB performance …

Dosimetric evaluation of Acuros XB Advanced Dose Calculation algorithm in heterogeneous media

A Fogliata, G Nicolini, A Clivio, E Vanetti, L Cozzi - Radiation oncology, 2011 - Springer
Background A study was realised to evaluate and determine relative figures of merit of a
new algorithm for photon dose calculation when applied to inhomogeneous media. Methods …

Clinical implementation of full Monte Carlo dose calculation in proton beam therapy

H Paganetti, H Jiang, K Parodi… - Physics in Medicine …, 2008 - iopscience.iop.org
The goal of this work was to facilitate the clinical use of Monte Carlo proton dose calculation