[HTML][HTML] A reactive power-based adaptive approach for synchronization of DFIG into the weak grid to support existing WE infrastructure

GS Chawda, AG Shaik - International Journal of Electrical Power & Energy …, 2024 - Elsevier
The synchronization of the Doubly-Fed Induction Generator (DFIG) into the weak AC grid is
significantly affected due to the reactive power limitations associated with the built-in …

Observer-based adaptive control and stabilization of grid-tied inverters under PLL nonlinearities and weak grid

R Debnath, GS Gupta, D Kumar - Electrical Engineering, 2023 - Springer
In a distributed generation system, the nonlinear dynamics of a grid-interfaced inverter (GII)
cause dynamic instability and power quality issues. Because traditional linear approaches …

Experimental validation of second-order adaptive fuzzy logic controller for grid-connected DFIG wind power plant

BE Elnaghi, MN Abelwhab, FESA Abdel-Kader… - IEEE …, 2023 - ieeexplore.ieee.org
This paper introduces a second-order adaptive fuzzy logic controller (SO-AFLC) to enhance
the characteristics of a doubly fed induction generator (DFIG) inside a grid-tied wind power …

Experimental study of fault impact on grid connected DFIG driven wind Turbine

S Gupta, A Shukla - 2022 IEEE Global Conference on …, 2022 - ieeexplore.ieee.org
Renewable energy is expanding rapidly with the goal of carbon neutrality, and research is
focusing on incorporating solar, wind, and other renewable resources for producing power …

The Validation and Implementation of the Second-Order Adaptive Fuzzy Logic Controller of a Double-Fed Induction Generator in an Oscillating Water Column

BE Elnaghi, MN Abelwhab, RH Mohammed… - Electronics, 2024 - mdpi.com
This article presents a second-order adaptive fuzzy logic controller (SO-AFLC) to improve
the performance of a grid-connected double-fed induction generator (DFIG) in an oscillating …

LMI-based state feedback control structure for resolving grid connectivity issues in DFIG-based WT systems

MAS Ali - Eng, 2021 - mdpi.com
Pertaining to the connectivity issues in wind power plants with grids, this study introduces an
efficient mechanism based on a state feedback control structure to establish a fast and …

A sensorless control strategy for automatic start‐up and grid‐synchronization of doubly fed induction generator in wind energy conversion system

SS Rauth, D Kastha, P Bajpai - International Journal of Circuit …, 2024 - Wiley Online Library
In a wind energy conversion system (WECS) based on a doubly fed induction generator
(DFIG), a fast and smooth automatic synchronization of the DFIG with the utility grid is always …

[PDF][PDF] Proposed synchronization circuits connecting wind driven DFIG to the public grid

MH Agamy, FM Allythi, AS Nada - International Journal of Power …, 2021 - academia.edu
This paper presents a tested proposal scheme to connect a DFIG driven by a wind turbine to
the public grid. This scheme was implemented to drive an automatic transfer switch (ATS) …

PERFORMANCE OF DOUBLY FED INDUCTION GENERATOR DRIVEN BY WIND ENERGY AT CONSTANT STATOR POWER AND CURRENT

MH Agamy, FM Ellyth, AS Nada… - Journal of Al-Azhar …, 2021 - jaes.journals.ekb.eg
This paper discusses the performance of a wind-driven doubly-fed induction generator when
connected to the grid. The stator is directly connected to the grid, while the rotor side …