CFD studies on the spread of ammonia and hydrogen sulfide pollutants in a public toilet under personalized ventilation
Z Zhang, L Zeng, H Shi, H Liu, W Yin, J Gao… - Journal of Building …, 2022 - Elsevier
The indoor environments of severely polluted toilets are associated with an increased risk of
transmission of severe diseases. Enhancing the ventilation effectiveness can improve the …
transmission of severe diseases. Enhancing the ventilation effectiveness can improve the …
[HTML][HTML] Multitarget control models for building thermal comfort and indoor air quality-A critical review
The control techniques in buildings contribute significantly to thermal comfort and indoor air
quality (IAQ). However, the gaps are existing for multitarget controls considering both …
quality (IAQ). However, the gaps are existing for multitarget controls considering both …
Investigating changes in geometric dimensions of vortex zones at the inlet of an exhaust hood set over a plane
KI Logachev, AM Ziganshin, Y Huang, Y Wang… - Building and …, 2022 - Elsevier
Local exhaust ventilation systems are the most effective–yet power-consuming–method of
capturing contaminants. Sha** of the ventilation ductwork elements is an approach that is …
capturing contaminants. Sha** of the ventilation ductwork elements is an approach that is …
Effect of ambient interferences on the effectiveness of a wearable ventilation for reducing pollutant exposure
This paper explores a wearable ventilation for reducing pollutant exposure in industrial
environments. The effectiveness of a HAS (Head-mounted air supply) method while the …
environments. The effectiveness of a HAS (Head-mounted air supply) method while the …
Experiment determining pressure loss reduction using a shaped round exhaust hood
KI Logachev, AM Ziganshin, EN Popov… - Building and …, 2021 - Elsevier
In this study, we experimentally determined the local drag coefficient (LDC) of a round
exhaust hood that was improved with different shaped inlet sections along the boundaries of …
exhaust hood that was improved with different shaped inlet sections along the boundaries of …
Prompt design of direction air supply using CFD-based proper orthogonal decomposition method considering locally dense sample distribution
Achieving long-lasting and effective respiratory protection in highly polluted industrial sites
with a cost of a small amount of air, particularly during mobile operations by workers, poses …
with a cost of a small amount of air, particularly during mobile operations by workers, poses …
[HTML][HTML] Reduced-scale experimental investigation on flow field characteristics of exhaust hood of double helix lifting transportation equipment in an industrial plant
Y Liu, L Bao, H Wang, A Yu, C Ge - Case Studies in Thermal Engineering, 2023 - Elsevier
In this study, the double screw lifting device of a rubber factory is taken as the case study
object, and a scale model experiment was designed to determine the temperature field …
object, and a scale model experiment was designed to determine the temperature field …
Numerical investigation on particle removal and energy consumption of supplied and recirculated ventilation for industrial workshop
C Lan, Y Diao - Indoor and Built Environment, 2023 - journals.sagepub.com
In the weld back-cleaning process, many high-concentration pollutants are produced, which
can lead to health problems after prolonged exposure. In this study, a novel recirculating …
can lead to health problems after prolonged exposure. In this study, a novel recirculating …
Air movement acceptability of a wearable ventilation for reducing pollutant exposure
Wearable ventilation reduces pollutant exposure by increasing the air supply, while wearers
should have an upper acceptable limit for the air supply velocity. This paper investigated the …
should have an upper acceptable limit for the air supply velocity. This paper investigated the …
Direction air supply design and optimization in industrial settings to reduce gaseous contaminant exposure
Y Xu, C Cao, M Ma, Z Jiao, L Cheng, W **e… - Building and …, 2022 - Elsevier
Ventilation systems designed for pollution removal in high-polluting workshops are usually
ineffective due to the movement of workers. This work proposes a novel design method for …
ineffective due to the movement of workers. This work proposes a novel design method for …