Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
[HTML][HTML] Impact of double skin facade constructional features on heat transfer and fluid dynamic behaviour
Double skin facades (DSF) are an interesting and important architectural element in
buildings as they are visually very attractive and can, at the same time, lead to better …
buildings as they are visually very attractive and can, at the same time, lead to better …
Influence of natural ventilation due to buoyancy and heat transfer in the energy efficiency of a double skin facade building
E Sanchez, A Rolando, R Sant, L Ayuso - Energy for sustainable …, 2016 - Elsevier
In recent years, the interest in double skin facades has increased because of esthetic
reasons and for its use as passive system to save energy. Some authors have investigated …
reasons and for its use as passive system to save energy. Some authors have investigated …
Design and low energy ventilation solutions for atria in the tropics
A generic atrium building was designed to incorporate low energy solutions and features of
both vernacular and contemporary South Asian architecture. To achieve low energy and …
both vernacular and contemporary South Asian architecture. To achieve low energy and …
[HTML][HTML] Parametric energy optimization of a ventilated facade with windows in Mediterranean climates
Ventilated facades are an effective passive measure to improve the energy performance of
buildings in warm and temperate climates such as the Mediterranean. However, although in …
buildings in warm and temperate climates such as the Mediterranean. However, although in …
Experimental study on thermal buoyancy-induced natural ventilation
It is well known that natural ventilation is caused by the outdoor wind velocity and the indoor-
outdoor temperature difference. Generally, natural ventilation is rarely caused by one effect …
outdoor temperature difference. Generally, natural ventilation is rarely caused by one effect …
[HTML][HTML] A review of airflow rate estimation techniques for natural ventilation in buildings
As natural ventilation involves local and global interactions, the estimation of these
interactions can be performed by many approaches. Such approaches, rather more …
interactions can be performed by many approaches. Such approaches, rather more …
[PDF][PDF] Multi-Method Fault Detection of Cooling Fan in Control Cabinet using Temperature Analysis
MK Odena, LB Hansen - 2023 - projekter.aau.dk
This report details the development of diverse fault detection and diagnosis algorithms
employed for detecting faults in cooling fans utilized for temperature management in control …
employed for detecting faults in cooling fans utilized for temperature management in control …
[PDF][PDF] ИЗСЛЕДВАНЕ НА АЕРОДИМНАМИЧНИТЕ ХАРАКТЕРИСТИКИ НА ВЕТРОВЕНТИЛАТОРИ ЗА ПРОВЕТРЯВАНЕ НА ПОДЗЕМНИ ОБЕКТИ
Z Dinchev, M Michaylov, E Vlasseva - researchgate.net
Paper presents experimental results of continuous work on wind turbine applications in
mining and other industrial activities. Following previous research on construction …
mining and other industrial activities. Following previous research on construction …
[PDF][PDF] Heating, Cooling and Ventilating Systems for Low-Carbon Buildings 4. s46 Department of Architecture Spring 2018
TAI Turan - mit.edu
Consensus understanding of climate change identifies a need to drastically reduce
anthropogenic emissions of greenhouse gases in coming decades, including those …
anthropogenic emissions of greenhouse gases in coming decades, including those …
Passive design approach in enhancing natural ventilation performance of two storeys residential buildings in tropical climate
I Abd Wahab - 2018 - eprints.uthm.edu.my
Air movement is one of the main factors contributing to thermal comfort. In achieving the
comfort while maintaining low energy consumption, natural ventilation is the best source of …
comfort while maintaining low energy consumption, natural ventilation is the best source of …