Clinical and technical challenges of prosthesis–patient mismatch after transcatheter aortic valve implantation
Prosthesis–patient mismatch (PPM) is present when the effective area of a prosthetic valve
inserted into a patient is inferior to that of a normal human valve; the hemodynamic …
inserted into a patient is inferior to that of a normal human valve; the hemodynamic …
Prognosis of severe low-flow, low-gradient aortic stenosis by stroke volume index and transvalvular flow rate
Objectives This study determined whether flow state classified by stroke volume index (SVi)
or transvalvular flow rate (FR) improved risk stratification of all-cause mortality …
or transvalvular flow rate (FR) improved risk stratification of all-cause mortality …
Management of the peri-intubation period in patients with pulmonary arterial hypertension and respiratory failure
AI Papolos, BB Kenigsberg, DR Austin… - Current Cardiology …, 2024 - Springer
Abstract Purpose of Review The endotracheal intubation of patients with pulmonary arterial
hypertension (PAH) in respiratory distress is a highly morbid procedure that can precipitate …
hypertension (PAH) in respiratory distress is a highly morbid procedure that can precipitate …
Left ventricular outflow tract velocity-time integral improves outcome prediction in patients with secondary mitral regurgitation
Aims Left ventricular outflow velocity-time integral (LVOT-VTI) has been shown to improve
outcome prediction in different patients' subsets, with or without heart failure (HF) …
outcome prediction in different patients' subsets, with or without heart failure (HF) …
Association of myocardial fibrosis and stroke volume by cardiovascular magnetic resonance in patients with severe aortic stenosis with outcome after valve …
Importance Low-flow severe aortic stenosis (AS) has higher mortality than severe AS with
normal flow. The conventional definition of low-flow AS is an indexed stroke volume (SVi) by …
normal flow. The conventional definition of low-flow AS is an indexed stroke volume (SVi) by …
Slice positioning in phase-contrast MRI impacts aortic stenosis assessment
Aims To determine the phase-contrast cardiovascular magnetic resonance imaging (PC-
CMR) slice-position above aortic leaflet-attachment-plane (LAP) that provides flow-velocity …
CMR) slice-position above aortic leaflet-attachment-plane (LAP) that provides flow-velocity …
[HTML][HTML] A novel approach to determine aortic valve area with phase-contrast cardiovascular magnetic resonance
Background Transthoracic echocardiography (TTE) is the diagnostic routine standard for
assessing aortic stenosis (AS). However, its inaccuracies in determining stroke volume (SV) …
assessing aortic stenosis (AS). However, its inaccuracies in determining stroke volume (SV) …
Cardiac output, cerebral blood flow and cognition in patients with severe aortic valve stenosis undergoing transcatheter aortic valve implantation: design and rationale …
AC Van Nieuwkerk, KI Hemelrijk, EE Bron… - Netherlands Heart …, 2023 - Springer
Background Approximately one-third of patients with symptomatic severe aortic valve
stenosis who are scheduled for transcatheter aortic valve implantation (TAVI) have some …
stenosis who are scheduled for transcatheter aortic valve implantation (TAVI) have some …
Measurement of stroke volume with echocardiography compared to gold standard cardiac magnetic resonance imaging: an observational study
B Cowie, L Wright, B Costello, K Janssens… - … of Cardiothoracic and …, 2023 - Elsevier
Objectives The authors aimed to compare the assessment of left ventricular (LV) stroke
volume with transthoracic echocardiography (TTE) using 2-and 3-dimensional (2D and 3D) …
volume with transthoracic echocardiography (TTE) using 2-and 3-dimensional (2D and 3D) …
Core Laboratory Versus Center‐Reported Echocardiographic Assessment of the Native and Bioprosthetic Aortic Valve
BJJ Velders, MD Vriesendorp, NJ Weissman… - …, 2024 - Wiley Online Library
Background Insights into quantitative differences between core laboratory and center‐
reported echocardiographic assessment of the native and bioprosthetic aortic valve are …
reported echocardiographic assessment of the native and bioprosthetic aortic valve are …