kV-Cone-beam-CT-basierte bildgeführte Strahlentherapie–ein klinischer Überblick: A Clinical Review

J Boda-Heggemann, F Lohr, F Wenz, M Flentje… - Strahlentherapie und …, 2011 - Springer
Abstract Aims and Methods: Delivery of high radiation doses while simultaneously sparing
organs at risk requires advanced imaging for target volume definition, highly conformal dose …

Image-guided radiotherapy: has it influenced patient outcomes?

A Bujold, T Craig, D Jaffray, LA Dawson - Seminars in radiation oncology, 2012 - Elsevier
Cancer control and toxicity outcomes are the mainstay of evidence-based medicine in
radiation oncology. However, radiotherapy is an intricate therapy involving numerous …

Quality assurance for image‐guided radiation therapy utilizing CT‐based technologies: a report of the AAPM TG‐179

JP Bissonnette, PA Balter, L Dong, KM Langen… - Medical …, 2012 - Wiley Online Library
Purpose: Commercial CT‐based image‐guided radiotherapy (IGRT) systems allow
widespread management of geometric variations in patient setup and internal organ motion …

The management of imaging dose during image‐guided radiotherapy: report of the AAPM Task Group 75

MJ Murphy, J Balter, S Balter, JA BenComo Jr… - Medical …, 2007 - Wiley Online Library
Radiographic image guidance has emerged as the new paradigm for patient positioning,
target localization, and external beam alignment in radiotherapy. Although widely varied in …

Image guidance doses delivered during radiotherapy: Quantification, management, and reduction: Report of the AAPM Therapy Physics Committee Task Group 180

GX Ding, P Alaei, B Curran, R Flynn… - Medical …, 2018 - Wiley Online Library
Background With radiotherapy having entered the era of image guidance, or image‐guided
radiation therapy (IGRT), imaging procedures are routinely performed for patient positioning …

Compressed sensing based cone‐beam computed tomography reconstruction with a first‐order method a

K Choi, J Wang, L Zhu, TS Suh, S Boyd… - Medical …, 2010 - Wiley Online Library
Purpose: This article considers the problem of reconstructing cone‐beam computed
tomography (CBCT) images from a set of undersampled and potentially noisy projection …

GPU-based iterative cone-beam CT reconstruction using tight frame regularization

X Jia, B Dong, Y Lou, SB Jiang - Physics in Medicine & Biology, 2011 - iopscience.iop.org
The x-ray imaging dose from serial cone-beam computed tomography (CBCT) scans raises
a clinical concern in most image-guided radiation therapy procedures. It is the goal of this …

Radiation dose from cone beam computed tomography for image-guided radiation therapy

MWK Kan, LHT Leung, W Wong, N Lam - International Journal of Radiation …, 2008 - Elsevier
PURPOSE: To perform a comprehensive study on organ absorbed doses and effective
doses from cone beam computed tomography (CBCT) for three different treatment sites …

Iterative image reconstruction for CBCT using edge‐preserving prior

J Wang, T Li, L **ng - Medical physics, 2009 - Wiley Online Library
On‐board cone‐beam computed tomography (CBCT) is a new imaging technique for
radiation therapy guidance, which provides volumetric information of a patient at treatment …

A review of cone-beam CT applications for adaptive radiotherapy of prostate cancer

M Posiewnik, T Piotrowski - Physica medica, 2019 - Elsevier
Introduction The aim of this study was to systematize the information on adaptive
radiotherapy based on cone-beam computed tomography (CBCT) imaging for patients with …