Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
Digital repetitive control of a three-phase four-wire shunt active filter
Shunt active power filters have been proved as useful elements to correct distorted currents
caused by nonlinear loads in power distribution systems. This paper presents an all-digital …
caused by nonlinear loads in power distribution systems. This paper presents an all-digital …
Odd-harmonic digital repetitive control of a single-phase current active filter
Shunt active power filters have been proved as useful elements to correct distorted currents
caused by nonlinear loads in power distribution systems. This work presents an all-digital …
caused by nonlinear loads in power distribution systems. This work presents an all-digital …
Robust adaptive parameter estimation of sinusoidal signals
A novel two step adaptive identification framework is proposed for sinusoidal signals to
estimate the unknown offset, amplitude, frequency and phase, where only the output …
estimate the unknown offset, amplitude, frequency and phase, where only the output …
A discrete-time repetitive sliding mode control for voltage source inverters
L Zheng, F Jiang, J Song, Y Gao… - IEEE Journal of emerging …, 2017 - ieeexplore.ieee.org
Voltage source inverters (VSIs), especially uninterrupted power supply for critical loads,
require high steady-state performance, fast transient response, and strong robustness …
require high steady-state performance, fast transient response, and strong robustness …
Plug-in dual-mode-structure repetitive controller for CVCF PWM inverters
Repetitive control (RC) is found to be a high-performance control scheme for constant-
voltage constant-frequency (CVCF) pulsewidth-modulated (PWM) converters to eliminate …
voltage constant-frequency (CVCF) pulsewidth-modulated (PWM) converters to eliminate …
A Repetitive-Based Controller for the Compensation of Harmonic Components
In this paper, a repetitive-based controller for the compensation of 6 lscr plusmn 1 harmonic
components is proposed. This control scheme is more appropriate for processes that involve …
components is proposed. This control scheme is more appropriate for processes that involve …
DSP-based implementation of an LQR with integral action for a three-phase three-wire shunt active power filter
B Kedjar, K Al-Haddad - IEEE transactions on industrial …, 2008 - ieeexplore.ieee.org
This paper presents the design and implementation of a linear quadratic regulator (LQR)
with integral action (LQRI) for a three-phase three-wire shunt active filter (SAF). The integral …
with integral action (LQRI) for a three-phase three-wire shunt active filter (SAF). The integral …
A survey on robust repetitive control and applications
Tracking and rejecting periodic signals are common tasks in many control applications. A
well-known use of Repetitive Control (RC) is to both track a periodic reference signal and …
well-known use of Repetitive Control (RC) is to both track a periodic reference signal and …
A three-phase UPS that complies with the standard IEC 62040-3
F Botterón, H Pinheiro - IEEE Transactions on Industrial …, 2007 - ieeexplore.ieee.org
This paper proposes a down-sampled discrete-time internal-model-based controller in the
synchronous reference frame with a reduced number of poles. This controller is suitable for …
synchronous reference frame with a reduced number of poles. This controller is suitable for …
[KIRJA][B] Periodic control of power electronic converters
Frede Blaabjerg is an IEEE Fellow and Professor in power electronics and drives at Aalborg
University, Department of Energy Technology, Denmark; his research interests include …
University, Department of Energy Technology, Denmark; his research interests include …