AAPM TG 191: Clinical use of luminescent dosimeters: TLDs and OSLDs
Thermoluminescent dosimeters (TLD) and optically stimulated luminescent dosimeters
(OSLD) are practical, accurate, and precise tools for point dosimetry in medical physics …
(OSLD) are practical, accurate, and precise tools for point dosimetry in medical physics …
Report of the AAPM Task Group No. 105: Issues associated with clinical implementation of Monte Carlo‐based photon and electron external beam treatment planning
The Monte Carlo (MC) method has been shown through many research studies to calculate
accurate dose distributions for clinical radiotherapy, particularly in heterogeneous patient …
accurate dose distributions for clinical radiotherapy, particularly in heterogeneous patient …
[ΒΙΒΛΙΟ][B] Handbook of radiotherapy physics: theory and practice
P Mayles, A Nahum, JC Rosenwald - 2007 - taylorfrancis.com
From background physics and biological models to the latest imaging and treatment
modalities, the Handbook of Radiotherapy Physics: Theory and Practice covers all …
modalities, the Handbook of Radiotherapy Physics: Theory and Practice covers all …
Dosimetric effects caused by couch tops and immobilization devices: report of AAPM Task Group 176
The dosimetric impact from devices external to the patient is a complex combination of
increased skin dose, reduced tumor dose, and altered dose distribution. Although small …
increased skin dose, reduced tumor dose, and altered dose distribution. Although small …
In vivo dosimetry during external photon beam radiotherapy
M Essers, BJ Mijnheer - … Journal of Radiation Oncology* Biology* Physics, 1999 - Elsevier
In this critical review of the current practice of patient dose verification, we first demonstrate
that a high accuracy (about 1–2%, 1 SD) can be obtained. Accurate in vivo dosimetry is …
that a high accuracy (about 1–2%, 1 SD) can be obtained. Accurate in vivo dosimetry is …
Accurate skin dose measurements using radiochromic film in clinical applications
Megavoltage x‐ray beams exhibit the well‐known phenomena of dose buildup within the
first few millimeters of the incident phantom surface, or the skin. Results of the surface dose …
first few millimeters of the incident phantom surface, or the skin. Results of the surface dose …
Integrating a MRI scanner with a 6 MV radiotherapy accelerator: impact of the surface orientation on the entrance and exit dose due to the transverse magnetic field
At the UMC Utrecht, in collaboration with Elekta and Philips Research Hamburg, we are
develo** a radiotherapy accelerator with integrated MRI functionality. The radiation dose …
develo** a radiotherapy accelerator with integrated MRI functionality. The radiation dose …
Applications of thermoluminescence dosimetry in medicine
T Kron - Radiation protection dosimetry, 1999 - academic.oup.com
Thermoluminescence dosimetry (TLD) features many advantages such as small detector
size and close tissue equivalence that make it useful for a variety of applications in …
size and close tissue equivalence that make it useful for a variety of applications in …
Measurement of radiotherapy x‐ray skin dose on a chest wall phantom
KY Quach, J Morales, MJ Butson… - Medical …, 2000 - Wiley Online Library
Sufficient skin dose needs to be delivered by a radiotherapy chest wall treatment regimen to
ensure the probability of a near surface tumor recurrence is minimized. To simulate a chest …
ensure the probability of a near surface tumor recurrence is minimized. To simulate a chest …
Skin dose during radiotherapy: a summary and general estimation technique
SF Kry, SA Smith, R Weathers… - Journal of applied clinical …, 2012 - Wiley Online Library
The skin dose associated with radiotherapy may be of interest for clinical evaluation or
investigating the risk of late effects. However, skin dose is not intuitive and is difficult to …
investigating the risk of late effects. However, skin dose is not intuitive and is difficult to …