Physics and biology of ultrahigh dose-rate (FLASH) radiotherapy: a topical review
N Esplen, MS Mendonca… - Physics in Medicine & …, 2020 - iopscience.iop.org
Ultrahigh dose-rate radiotherapy (RT), or'FLASH'therapy, has gained significant momentum
following various in vivo studies published since 2014 which have demonstrated a reduction …
following various in vivo studies published since 2014 which have demonstrated a reduction …
Semiconductor dosimetry in modern external-beam radiation therapy
Semiconductor dosimeters are ubiquitous in modern external-beam radiation therapy. They
possess key features. The response, electronically available in real time, is stable and linear …
possess key features. The response, electronically available in real time, is stable and linear …
[BOOK][B] Radiation Dosimetry Instrumentation and Methods (2001)
G Shani - 2017 - taylorfrancis.com
Radiation dosimetry has made great progress in the last decade, mainly because radiation
therapy is much more widely used. Since the first edition, many new developments have …
therapy is much more widely used. Since the first edition, many new developments have …
Electronic dosimetry in radiation therapy
AB Rosenfeld - Radiation measurements, 2006 - Elsevier
Radiation therapy became more and more sophisticated in terms of radiation oncology
modalities, type of radiation used and method of delivery that is leading to very conformal …
modalities, type of radiation used and method of delivery that is leading to very conformal …
MOSFET dosimetry for microbeam radiation therapy at the European Synchrotron Radiation Facility
Preclinical experiments are carried out with∼ 20–30 μm wide,∼ 10 mm high parallel
microbeams of hard, broad‐“white”‐spectrum x rays (∼ 50–600 keV) to investigate …
microbeams of hard, broad‐“white”‐spectrum x rays (∼ 50–600 keV) to investigate …
High spatial resolution scintillator dosimetry of synchrotron microbeams
Microbeam radiation therapy is a novel pre-clinical external beam therapy that uses high-
brilliance synchrotron X-rays to deliver the necessary high dose rates. The unique …
brilliance synchrotron X-rays to deliver the necessary high dose rates. The unique …
P-channel MOSFET as ionizing radiation detector
MM Pejović, SM Pejović - Applied Radiation and Isotopes, 2023 - Elsevier
In this study, the authors examine the responses of radiation-sensitive p-channel MOSFETs
to irradiation and subsequent annealing at room temperature and higher temperatures to …
to irradiation and subsequent annealing at room temperature and higher temperatures to …
[BOOK][B] Radiation sensors with 3D electrodes
C Da Vià, GF Dalla Betta, S Parker - 2019 - taylorfrancis.com
Written by the leading names in this field, this book introduces the technical properties,
design and fabrication details, measurement results, and applications of three-dimensional …
design and fabrication details, measurement results, and applications of three-dimensional …
X-Tream: a novel dosimetry system for Synchrotron Microbeam Radiation Therapy
M Petasecca, A Cullen, I Fuduli… - Journal of …, 2012 - iopscience.iop.org
Abstract Microbeam Radiation Therapy (MRT) is a radiation treatment technique under
development for inoperable brain tumors. MRT is based on the use of a synchrotron …
development for inoperable brain tumors. MRT is based on the use of a synchrotron …
Microstrip plastic scintillating detector system for quality assurance in synchrotron microbeam radiotherapy
Synchrotron microbeam radiotherapy (MRT), which has entered the clinical transfer phase,
requires the development of appropriate quality assurance (QA) tools due to very high dose …
requires the development of appropriate quality assurance (QA) tools due to very high dose …