Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
Behavioral characteristics of RC beams with non-uniform corrosion along the reinforcement
X Zhu, H Abe, D Hayashi… - Journal of Intelligent …, 2023 - ieeexplore.ieee.org
This study investigated the behavior of a non-corroded reinforced concrete (RC) beam and
two RC beams with non-uniform corrosion (whole span and side span) in a four-point …
two RC beams with non-uniform corrosion (whole span and side span) in a four-point …
Chloride-induced corrosion of steel reinforcement–Mechanical performance and pit depth analysis
In the current study the effects of chloride-induced corrosion, in terms of mechanical
properties and pit depths, are evaluated on B500c steel bars embedded in concrete …
properties and pit depths, are evaluated on B500c steel bars embedded in concrete …
A step towards standardising accelerated corrosion tests on laboratory reinforced concrete specimens
Natural steel corrosion of reinforced concrete (RC) structures is a slow process which
researchers find necessary to accelerate in laboratory tests to obtain needed damage in a …
researchers find necessary to accelerate in laboratory tests to obtain needed damage in a …
Modelling of interaction between corrosion-induced concrete cover crack and steel corrosion rate
C Cao, MMS Cheung, BYB Chan - Corrosion Science, 2013 - Elsevier
Chloride-induced corrosion of steel reinforcement in concrete may cause severe damage to
RC structures. This paper examines the interaction between corrosion-induced cover crack …
RC structures. This paper examines the interaction between corrosion-induced cover crack …
Corrosion characteristics of a 4-year naturally corroded reinforced concrete beam with load-induced transverse cracks
This work studies the corrosion characteristics of reinforcement in a 4-year naturally
corroded concrete beam after accelerated chloride penetration. The results show that the …
corroded concrete beam after accelerated chloride penetration. The results show that the …
Prediction of reinforcement corrosion using corrosion induced cracks width in corroded reinforced concrete beams
This paper studies the evolution of reinforcement corrosion in comparison to corrosion crack
width in a highly corroded reinforced concrete beam. Cracking and corrosion maps of the …
width in a highly corroded reinforced concrete beam. Cracking and corrosion maps of the …
Bond degradation of non-uniformly corroded steel rebars in concrete
In this work, the bond degradation of non-uniformly corroded steel rebars embedded in
concrete was studied. A total of 105 concrete specimens with accelerated corrosion of steel …
concrete was studied. A total of 105 concrete specimens with accelerated corrosion of steel …
Correlation between concrete cracks and corrosion characteristics of steel reinforcement in pre-cracked plain and fibre-reinforced concrete beams
This paper presents results on corrosion characteristics of 66 rebars extracted from un-and
pre-cracked plain concrete and fibre-reinforced concrete (FRC) beams suffering from …
pre-cracked plain concrete and fibre-reinforced concrete (FRC) beams suffering from …
Lifetime seismic performance of concrete bridges exposed to corrosion
This paper presents a probabilistic approach to predict the lifetime seismic performance of
concrete bridges exposed to aggressive environments. The time-variant behaviour of critical …
concrete bridges exposed to aggressive environments. The time-variant behaviour of critical …
[HTML][HTML] Assessment of the mechanical behaviour of reinforcement bars with localised pitting corrosion by digital image correlation
Corrosion of reinforcement in concrete impairs the mechanical behaviour of rebars by
decreasing their strength and deformation capacity. In this study, uniaxial tensile tests were …
decreasing their strength and deformation capacity. In this study, uniaxial tensile tests were …