Current status and future trends in frequency-response analysis with a transformer in service

E Gomez-Luna, GA Mayor… - … on power delivery, 2013 - ieeexplore.ieee.org
This paper presents the current status and future trends in the application of the frequency-
response analysis (FRA) technique with the transformer in service (online) through …

[PDF][PDF] Wavelet transform for processing power quality disturbances

S Chen, HY Zhu - EURASIP Journal on Advances in Signal Processing, 2007 - Springer
The emergence of power quality as a topical issue in power systems in the 1990s largely
coincides with the huge advancements achieved in the computing technology and …

Modeling and experimental verification of high impedance arcing fault in medium voltage networks

NI Elkalashy, M Lehtonen, HA Darwish… - … on Dielectrics and …, 2007 - ieeexplore.ieee.org
A high impedance arcing fault due to a leaning tree in medium voltage (MV) networks is
modeled and experimentally verified. The fault is represented in two parts; an arc model and …

Synchronous waveform measurements to locate transient events and incipient faults in power distribution networks

M Izadi, H Mohsenian-Rad - IEEE Transactions on Smart Grid, 2021 - ieeexplore.ieee.org
A new method is proposed to identify the location of transient events, including incipient
faults, in power distribution systems, by using synchronized measurements from an …

Integrated DWT–FFT approach for detection and classification of power quality disturbances

SA Deokar, LM Waghmare - International Journal of Electrical Power & …, 2014 - Elsevier
The signals in the electrical power system always have some power quality disturbances
and noise contents which is the biggest obstacle in detection and time localization. In this …

A novel approach to detect symmetrical faults occurring during power swings by using frequency components of instantaneous three-phase active power

B Mahamedi, JG Zhu - IEEE Transactions on Power Delivery, 2012 - ieeexplore.ieee.org
Since distance relays are prone to interpret a power swing as a three-phase fault, they
should be blocked during the power swing to prevent undesired trips. On the other hand, if …

Fault detection and diagnosis of a 12-cylinder trainset diesel engine based on vibration signature analysis and neural network

A Zabihi-Hesari, S Ansari-Rad… - Proceedings of the …, 2019 - journals.sagepub.com
This paper presents a condition monitoring and combustion fault detection technique for a
12-cylinder 588 kW trainset diesel engine based on vibration signature analysis using fast …

A new method for discrimination of internal fault from other transient states in power transformer using Clarke's transform and modified hyperbolic S-transform

A Behvandi, SG Seifossadat, A Saffarian - Electric Power Systems …, 2020 - Elsevier
In this paper, a new method is proposed for discriminating internal faults from other
abnormal conditions in power transformers such as inrush currents, external faults, over …

Hyperbolic S-transform-based method for classification of external faults, incipient faults, inrush currents and internal faults in power transformers

A Ashrafian, M Rostami, GB Gharehpetian - IET generation, transmission & …, 2012 - IET
In this study, a hyperbolic S-transform-based method is proposed to discriminate most
important transient fault currents of transformers. First, the proposed method discriminates …

Detection method of interturn short-circuit faults in oil-immersed transformers based on fusion analysis of electrothermal characteristic

Z Li**g, S Gehao, H Huijuan… - Power System …, 2021 - epjournal.csee.org.cn
The existing methods of interturn fault diagnosis of a power transformer depend on the
single signal indicator such as the winding current, the impendence or the dissolved gases …