[HTML][HTML] Report dose-to-medium in clinical trials where available; a consensus from the Global Harmonisation Group to maximize consistency
Purpose To promote consistency in clinical trials by recommending a uniform framework as
it relates to radiation transport and dose calculation in water versus in medium. Methods The …
it relates to radiation transport and dose calculation in water versus in medium. Methods The …
Beam modeling and beam model commissioning for Monte Carlo dose calculation‐based radiation therapy treatment planning: Report of AAPM Task Group 157
Dose calculation plays an important role in the accuracy of radiotherapy treatment planning
and beam delivery. The Monte Carlo (MC) method is capable of achieving the highest …
and beam delivery. The Monte Carlo (MC) method is capable of achieving the highest …
AAPM Task Group 329: reference dose specification for dose calculations: dose‐to‐water or dose‐to‐muscle?
Linac calibration is done in water, but patients are comprised primarily of soft tissue.
Conceptually, and specified in NRG/RTOG trials, dose should be reported as dose‐to …
Conceptually, and specified in NRG/RTOG trials, dose should be reported as dose‐to …
[HTML][HTML] Dosimetric impact of Acuros XB dose-to-water and dose-to-medium reporting modes on lung stereotactic body radiation therapy and its dependency on …
C Muñoz-Montplet, R Fuentes-Raspall… - Advances in Radiation …, 2021 - Elsevier
Purpose To assess the dosimetric impact of switching from the analytical anisotropic
algorithm (AAA) to Acuros XB (AXB), with dose-to-medium (Dm) and dose-to-water (Dw) …
algorithm (AAA) to Acuros XB (AXB), with dose-to-medium (Dm) and dose-to-water (Dw) …
Maintaining dosimetric quality when switching to a Monte Carlo dose engine for head and neck volumetric‐modulated arc therapy planning
V Feygelman, K Latifi, M Bowers… - Journal of Applied …, 2022 - Wiley Online Library
Head and neck cancers present challenges in radiation treatment planning due to the large
number of critical structures near the target (s) and highly heterogeneous tissue …
number of critical structures near the target (s) and highly heterogeneous tissue …
Radiochromic film dosimetry for protons up to 10 MeV with EBT2, EBT3 and unlaminated EBT3 films
D Sanchez-Parcerisa, I Sanz-García… - Physics in Medicine …, 2021 - iopscience.iop.org
Passive dosimetry with radiochromic films is widely used in proton radiotherapy, both in
clinical and scientific environments, thanks to its simplicity, high spatial resolution and dose …
clinical and scientific environments, thanks to its simplicity, high spatial resolution and dose …
Impact of the dose quantity used in MV photon optimization on dose distribution, robustness, and complexity
D Jurado‐Bruggeman, C Muñoz‐Montplet… - Medical …, 2022 - Wiley Online Library
Purpose Convolution/superposition algorithms used in megavoltage (MV) photon
radiotherapy model radiation transport in water, yielding dose to water‐in‐water (Dw, w) …
radiotherapy model radiation transport in water, yielding dose to water‐in‐water (Dw, w) …
[HTML][HTML] Measuring the dose in bone for spine stereotactic body radiotherapy
M Shaw, J Lye, A Alves, M Hanlon, J Lehmann… - Physica Medica, 2021 - Elsevier
Purpose Current quality assurance of radiotherapy involving bony regions generally utilises
homogeneous phantoms and dose calculations, ignoring the challenges of heterogeneities …
homogeneous phantoms and dose calculations, ignoring the challenges of heterogeneities …
Validation of two calculation options built in Elekta Monaco Monte Carlo based algorithm using MCNP code
Introduction The calculation algorithm for intensity modulated radiotherapy (IMRT) built in
the Elekta Monaco treatment planning system (TPS) is based on Monte Carlo (MC) …
the Elekta Monaco treatment planning system (TPS) is based on Monte Carlo (MC) …
[HTML][HTML] Using density computed tomography images for photon dose calculations in radiation oncology: A patient study
C Decoene, F Crop - Physics and Imaging in Radiation Oncology, 2023 - Elsevier
Background and purpose Conventional workflows for dose calculations require conversions
between Hounsfield Units (HU) and the mass or electron density for Computed Tomography …
between Hounsfield Units (HU) and the mass or electron density for Computed Tomography …