Estimation of physiological tremor from accelerometers for real-time applications

KC Veluvolu, WT Ang - Sensors, 2011 - mdpi.com
Accurate filtering of physiological tremor is extremely important in robotics assisted surgical
instruments and procedures. This paper focuses on develo** single stage robust …

Real-time estimation of pathological tremor parameters from gyroscope data

JA Gallego, E Rocon, JO Roa, JC Moreno, JL Pons - Sensors, 2010 - mdpi.com
This paper presents a two stage algorithm for real-time estimation of instantaneous tremor
parameters from gyroscope recordings. Gyroscopes possess the advantage of providing …

Development of a wearable tremor suppression glove

Y Zhou, ME Jenkins, MD Naish… - 2018 7th IEEE …, 2018 - ieeexplore.ieee.org
Current treatments for parkinsonian tremor, such as medication and brain surgery, have
shown varying levels of effectiveness and carry the risk of significant side effects and …

Estimation and filtering of physiological tremor for real‐time compensation in surgical robotics applications

KC Veluvolu, WT Ang - The International Journal of Medical …, 2010 - Wiley Online Library
Background Physiological tremor is the main cause of imprecision in microsurgical
procedures/robotics applications. Existing methods, such as weighted‐frequency Fourier …

Design and preliminary performance assessment of a wearable tremor suppression glove

Y Zhou, A Ibrahim, KG Hardy… - IEEE Transactions …, 2021 - ieeexplore.ieee.org
Objective: Approximately 25% of individualsliving with parkinsonian tremor do not respond
to traditional treatments. Wearable tremor suppression devices (WTSD) provide an …

Characterization of parkinsonian hand tremor and validation of a high-order tremor estimator

Y Zhou, ME Jenkins, MD Naish… - IEEE Transactions on …, 2018 - ieeexplore.ieee.org
Recent progress in wearable technology has made wearable tremor suppression devices
(WTSDs) for Parkinson's patients a potentially viable alternative solution for tremor …

Double adaptive bandlimited multiple Fourier linear combiner for real-time estimation/filtering of physiological tremor

KC Veluvolu, WT Latt, WT Ang - Biomedical Signal Processing and Control, 2010 - Elsevier
Tremor is the root cause for human imprecision during microsurgery. Accurate filtering of
physiological tremor is extremely important for compensation in robotics assisted …

Estimating displacement of periodic motion with inertial sensors

UX Tan, KC Veluvolu, WT Latt, CY Shee… - IEEE Sensors …, 2008 - ieeexplore.ieee.org
Inertial sensors, like accelerometers and gyroscopes, are rarely used by themselves to
measure displacement. Accuracy of inertial sensors is greatly handicapped by the notorious …

An effective tremor-filtering model in teleoperation: three-domain wavelet least square support vector machine

M Pan, Q Yang, T Su, K Geng, K Liang - Applied Soft Computing, 2022 - Elsevier
Proper elimination of hand tremors in robot-assisted minimally invasive surgery has become
a key concern due to its significant impacts on control precision and surgical success. In this …

Online censoring based weighted-frequency Fourier linear combiner for estimation of pathological hand tremors

EC Mengüç, S Çınar, M **ang… - IEEE Signal Processing …, 2021 - ieeexplore.ieee.org
An online censoring (OC) based weighted-frequency Fourier linear combiner (OC-WFLC)
adaptive filtering structure is proposed to reduce data processing costs in the estimation of …