Metal-on-metal bearings: the evidence so far
FS Haddad, RR Thakrar, AJ Hart… - The Journal of Bone …, 2011 - boneandjoint.org.uk
Lately, concerns have arisen following the use of large metal-on-metal bearings in hip
replacements owing to reports of catastrophic soft-tissue reactions resulting in implant failure …
replacements owing to reports of catastrophic soft-tissue reactions resulting in implant failure …
Molecular and immune toxicity of CoCr nanoparticles in MoM hip arthroplasty
HS Gill, G Grammatopoulos, S Adshead… - Trends in molecular …, 2012 - cell.com
Theoretical, desirable features of second-generation metal-on-metal (MoM) hip prostheses
have led to their widespread use. However, the bearing surfaces, consisting of complex …
have led to their widespread use. However, the bearing surfaces, consisting of complex …
High failure rates with a large-diameter hybrid metal-on-metal total hip replacement: clinical, radiological and retrieval analysis
B Bolland, DJ Culliford, DJ Langton… - The Journal of Bone …, 2011 - boneandjoint.org.uk
This study reports the mid-term results of a large-bearing hybrid metal-on-metal total hip
replacement in 199 hips (185 patients) with a mean follow-up of 62 months (32 to 83). Two …
replacement in 199 hips (185 patients) with a mean follow-up of 62 months (32 to 83). Two …
Pseudotumors are common in well-positioned low-wearing metal-on-metal hips
AK Matthies, JA Skinner, H Osmani… - Clinical Orthopaedics …, 2012 - journals.lww.com
Background Pseudotumors are sterile inflammatory lesions found in the soft tissues
surrounding metal-on-metal (MOM) and metal-on-polyethylene hip arthroplasties. In patients …
surrounding metal-on-metal (MOM) and metal-on-polyethylene hip arthroplasties. In patients …
Tribocorrosion response of the Ti6Al4V alloys commonly used in femoral stems
In prosthesis, tribochemical reactions occur at the stem/bone interface. When coupled with
micro-motions it can lead to the loosening of the implant, osteolysis, release of metal ion and …
micro-motions it can lead to the loosening of the implant, osteolysis, release of metal ion and …
Hip and knee section, diagnosis, algorithm: proceedings of international consensus on orthopedic infections
Question 1: Do you agree with the American Academy of Orthopaedic Surgeons algorithm
for the diagnosis of periprosthetic joint infections (PJIs)? Recommendation: Yes. However …
for the diagnosis of periprosthetic joint infections (PJIs)? Recommendation: Yes. However …
Pseudotumor formation and serum ions after large head metal-on-metal stemmed total hip replacement. Risk factors, time course and revisions in 706 hips
BH Bosker, HB Ettema, M Van Rossum… - Archives of orthopaedic …, 2015 - Springer
Introduction The incidence and natural course of pseudotumors in metal-on-metal total hip
arthroplasties is largely unknown. The objective of this study was to identify the true …
arthroplasties is largely unknown. The objective of this study was to identify the true …
Stability and trunnion wear potential in large-diameter metal-on-metal total hips: a finite element analysis
JM Elkins, JJ Callaghan, TD Brown - Clinical Orthopaedics and …, 2014 - journals.lww.com
Background Large-diameter femoral heads for metal-on-metal THA hold theoretical
advantages of joint stability and low bearing surface wear. However, recent reports have …
advantages of joint stability and low bearing surface wear. However, recent reports have …
Multi-material Ti6Al4V & PEEK cellular structures produced by Selective Laser Melting and Hot Pressing: A tribocorrosion study targeting orthopedic applications
Ti6Al4V-alloy is commonly used in dental and orthopedic applications where tribochemical
reactions occur at material/bone interface. These reactions are one of the main concerns …
reactions occur at material/bone interface. These reactions are one of the main concerns …
Bioengineering reasons for the failure of metal-on-metal hip prostheses: an engineer's perspective
J Fisher - The Journal of Bone & Joint Surgery British Volume, 2011 - boneandjoint.org.uk
Bioengineering reasons for increased wear and failure of metal-on-metal (MoM) bearings in
hip prostheses have been described. Low wear occurs in MoM hips when the centre of the …
hip prostheses have been described. Low wear occurs in MoM hips when the centre of the …