Biocompatibility of titanium from the viewpoint of its surface

T Hanawa - Science and Technology of Advanced Materials, 2022 - Taylor & Francis
Among metals, Ti and majority of its alloys exhibit excellent biocompatibility or tissue
compatibility. Although their high corrosion resistance is a factor in the biocompatibility of Ti …

Research and development of metals for medical devices based on clinical needs

T Hanawa - Science and technology of advanced materials, 2012 - iopscience.iop.org
The current research and development of metallic materials used for medicine and dentistry
is reviewed. First, the general properties required of metals used in medical devices are …

Shape memory alloys: Properties and biomedical applications

D Mantovani - Jom, 2000 - Springer
Shape memory alloys provide new insights for the design of biomaterials in bioengineering
for the design of artificial organs and advanced surgical instruments, since they have …

[HTML][HTML] Mechanical failure of prosthetic human implants: a 10-year experience with aortic stent graft devices

TS Jacobs, J Won, EC Gravereaux, PL Faries… - Journal of vascular …, 2003 - Elsevier
Objective: The first endovascular stent graft was implanted to treat an abdominal aortic
aneurysm more than a decade ago. This technique has evolved dramatically with the …

Corroded nitinol wires in explanted aortic endografts: an important mechanism of failure?

C Heintz, G Riepe, L Birken, E Kaiser… - Journal of …, 2001 - journals.sagepub.com
Purpose: To analyze surface alterations and fractures observed in the nitinol stent wires of
explanted endovascular grafts used for treatment of abdominal aortic aneurysm. Methods …

Surface conditions of Nitinol wires, tubing, and as‐cast alloys. The effect of chemical etching, aging in boiling water, and heat treatment

SA Shabalovskaya, J Anderegg, F Laab… - … Research Part B …, 2003 - Wiley Online Library
The surface conditions of Nitinol wires and tubing were evaluated with the use of X‐ray
photoelectron spectroscopy, high‐resolution Auger spectroscopy, electron backscattering …

Oxide layer formation, corrosion, and biocompatibility of nitinol cardiovascular devices

S Nagaraja, R Brown, D Saylor, A Undisz - Shape Memory and …, 2022 - Springer
Nitinol-based cardiovascular devices can undergo corrosion following placement in the
body and the resulting corrosion events may have potential implications on the mechanical …

[HTML][HTML] Outcomes of secondary interventions after abdominal aortic aneurysm endovascular repair

JP Becquemin, L Kelley, T Zubilewicz… - Journal of vascular …, 2004 - Elsevier
PURPOSE: We assessed the distribution of secondary interventions after aortic stent grafting
(EVAR) performed to treat infrarenal abdominal aortic aneurysm (AAA), and evaluated …

What can we learn from explanted endovascular devices?

G Riepe, C Heintz, E Kaiser, N Chakfé… - European journal of …, 2002 - Elsevier
Objective: to examine the durability of the Stentor® and Vanguard® endovascular devices in
human implants. Methods: the textile covering, the polypropylene ligatures and the stent …

Influence of stent design and material composition on procedure outcome

JC Palmaz, S Bailey, D Marton, E Sprague - Journal of vascular surgery, 2002 - Elsevier
Although intravascular stents have received widespread application, significant limitations
remain. In stent restenosis, the most pervasive problem affecting stents, is related in part to …