Fatigue resistance curves for single and double shear riveted joints from old Portuguese metallic bridges
The maintenance and safety of ancient bridges is a major concern of governmental
authorities. In particular, the safety of old riveted bridges fabricated and placed into service …
authorities. In particular, the safety of old riveted bridges fabricated and placed into service …
Corrosion fatigue failure analysis and service life prediction of high strength steel wire
S Xue, R Shen, W Chen, R Miao - Engineering Failure Analysis, 2020 - Elsevier
In this paper, corrosion fatigue failure of high-strength steel wire was studied based on the
actual cable or sling in the bridge, and the service life prediction formula considering the …
actual cable or sling in the bridge, and the service life prediction formula considering the …
Reliability analysis based on hybrid algorithm of M5 model tree and Monte Carlo simulation for corroded pipelines: Case of study X60 Steel grade pipes
In this paper, the failure probability of corroded pipelines made by X60 steel grade is
evaluated. For this complex real engineering failure problem, the burst corroded …
evaluated. For this complex real engineering failure problem, the burst corroded …
Corrosion fatigue and electrochemical behaviour of steel wires used in bridge cables
Z Liu, T Guo, X Yu, X Huang… - Fatigue & Fracture of …, 2021 - Wiley Online Library
In‐service bridge wires often fail prior to the design life subjected to alternating stresses and
environmental erosion. In this paper, a novel corrosion fatigue test device, integrating fatigue …
environmental erosion. In this paper, a novel corrosion fatigue test device, integrating fatigue …
Evaluation of tensile performance of steel members by analysis of corroded steel surface using deep learning
To conduct safety checks of corroded steel structures and formulate appropriate
maintenance strategies, the residual strength of steel structural members must be assessed …
maintenance strategies, the residual strength of steel structural members must be assessed …
Introducing the concept of defect tolerance by fatigue spectral methods based on full-field frequency response function testing and dynamic excitation signature
A Zanarini - International Journal of Fatigue, 2022 - Elsevier
The complete elimination of flaws in complex parts raises the overall costs, especially under
stringent safety or service targets, while advanced knowledge might grade the risk of …
stringent safety or service targets, while advanced knowledge might grade the risk of …
Role of hydrogen in operational degradation of pipeline steel
H Nykyforchyn, O Tsyrulnyk, O Zvirko… - Procedia Structural Integrity, 2020 - Elsevier
Long-term operation of oil and gas pipeline steels causes a significant worsening of their
mechanical properties, especially characteristics of brittle fracture resistance. General …
mechanical properties, especially characteristics of brittle fracture resistance. General …
Fatigue performance of an innovative shallow-buried modular bridge expansion joint
Bridge expansion joint can accommodate the deformation under the effects of vehicle load
and temperature. Fatigue damage readily occurs because it is directly subjected to repeated …
and temperature. Fatigue damage readily occurs because it is directly subjected to repeated …
Failure analysis of pearlitic rail steel with internal macrocrack after long-term operation
SA Atroshenko, VI Smirnov, SS Maier - Engineering Failure Analysis, 2022 - Elsevier
During operation, various physical and mechanical processes occur in the metal of the rails
under cyclic force action over time: plastic deformation of the rail rolling surface, the …
under cyclic force action over time: plastic deformation of the rail rolling surface, the …
Failure analysis of fatigue fracture for 60Si2Mn steel fastening clip in the track of high-speed railway
N Zhang, C Fu, B Jiang, L Sun, Y Liu - Engineering Failure Analysis, 2022 - Elsevier
A 60Si2Mn steel fastening clip in the track of high-speed railway fractured abnormally during
service, and its service life was 8 years. The microstructure and the fracture morphology of …
service, and its service life was 8 years. The microstructure and the fracture morphology of …