Design of chopper-stabilized amplifiers with reduced offset for sensor applications
PK Chan, J Cui - IEEE Sensors Journal, 2008 - ieeexplore.ieee.org
Offset error mechanisms in a single-ended chopper-stabilized amplifier are investigated.
The error models and their prediction equations are given. This work also presents a new …
The error models and their prediction equations are given. This work also presents a new …
A high-gain acquisition system with very large input range
R Rieger, YY Pan - IEEE Transactions on Circuits and Systems I …, 2008 - ieeexplore.ieee.org
A signal acquisition system is presented for the recording of small signals in the presence of
low-frequency interference. In a conventional design, high-pass filters precede the input …
low-frequency interference. In a conventional design, high-pass filters precede the input …
Design of low-power low-voltage biomedical amplifier for electrocardiogram signal recording
The demand for health-monitoring products is increasing worldwide. Low-power and low-
voltage attributes are important concerns that need to be addressed in circuits used for …
voltage attributes are important concerns that need to be addressed in circuits used for …
A Study on Source Degenerated Telescopic OpAmp for Biomedical Applications
This study outlines the potential use of a proposed tunable source degenerated telescopic
OpAmp for biomedical signal acquisition systems. Mathematical background is presented for …
OpAmp for biomedical signal acquisition systems. Mathematical background is presented for …
Pain induced by intensive light beam pulse stimulation of acupuncture point GB34 of lower extremities and its associated changes in EEG's
FS Lee, TA Chang, A Wu - Acupuncture & Electro-Therapeutics …, 2011 - ingentaconnect.com
Pain perception and its EEG wave have been used to describe the body's neural systemic
response with respect to a given stimulation. Pain artificially induced by non-coherent …
response with respect to a given stimulation. Pain artificially induced by non-coherent …
Análisis del papel de la electromiografía de superficie en las alteraciones de la deglución: una revisión sistemática
A Pérez del Olmo - 2024 - gredos.usal.es
[ES] La deglución es un proceso complejo que involucra la coordinación de músculos
orofaciales y faríngeos. Las alteraciones de este proceso pueden tener consecuencias que …
orofaciales y faríngeos. Las alteraciones de este proceso pueden tener consecuencias que …
A functional monitoring system for electrical safety of biochips
R Rieger - 2009 IEEE Biomedical Circuits and Systems …, 2009 - ieeexplore.ieee.org
A safe electrical connection between an integrated circuit and the human body is required
for the recording of physiological signals such as ECG, ENG, or EMG. The recording chip is …
for the recording of physiological signals such as ECG, ENG, or EMG. The recording chip is …
A bio-signal amplifier system with very-large dynamic-range
R Rieger, YY Pan - TENCON 2007-2007 IEEE Region 10 …, 2007 - ieeexplore.ieee.org
The recording of small signals such as body potentials requires high-gain amplification. In a
high-gain system even small offset voltages pose a problem when they saturate the …
high-gain system even small offset voltages pose a problem when they saturate the …
An ultra low-power cmos emg amplifier with high efficiency in operation frequency per power
GL Jaya, PK Chan - Proceedings of the 2009 12th International …, 2009 - ieeexplore.ieee.org
A new ultra low-power CMOS Electromyograph (EMG) amplifier is presented in this paper. It
is based on the application of a novel capacitive load reduction circuit technique to the …
is based on the application of a novel capacitive load reduction circuit technique to the …
A DC coupled signal acquisition system with ultra-wide input range
A signal acquisition system is presented which is suitable for small signals in the presence
of low-frequency interference. In a conventional design filters precede the input stage to …